ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 49
You now need to set up the last Data Output Record to log and transmit the average battery voltage. If
you examine the range of data that will come from the average battery voltage calculation, you will find
that it is very similar to the range set for average internal temperature. You can save yourself some typing
by using Data Output Record #3 to partially create Data Output Record #4, which will log and transmit
the average battery voltage. To save yourself some more typing, you can "copy and paste" Data Output
Record #3 into Data Output Record #4 by using menu options "C" for copy and "V" for paste.
48
When you create a new Data Output Record using the "A" command, you will be taken immediately to
the new Data Output Record. You can first type the "C" command to copy the contents of Data Output
Record #3. Then type the "A" command to create the new Data Output Record. Then type the "V"
command to copy the contents of the clipboard into Data Output Record #4. Rather than sending them
one at a time, you can send all three commands on a single command line to the ZENO
®
-3200. Type C A
V{ENTER} in the Data Output Menu for this Data Output Record.
49
Your screen should look the following:
> C A V
Record copied to clipboard.
DATA OUTPUT MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Data Items for Record 4 of 4:
Item 1: Field Type Code 9 : Transmit and Log Data Field
Item 2: Output Message(s) 1
Item 3: Field Name AvgTemp
Item 4: Input Record P1.1 : AvgTemp
Item 5: Field Decimal Places 1
Item 6: Field Width 6
Item 7: Data Storage Class Code 7 : 2-byte compressed float
>
Now, all you have to do is change the Field Name to "AvgBatt" and the Input Record to "P2.1" so that
this Data Output Record will log and transmit the average battery voltage calculated by Process Record
#2. Type C/AvgBatt C4/P2.1{ENTER} in the Data Output Menu for this Data Output Record.
48
Refer to Section 10.2.
49
Refer to Section 10.2.
Comentarios a estos manuales