> C1/6 C3/<D><A>SITE<20>1
DATA OUTPUT MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Data Items for Record 1 of 73:
Item 1: Field Type Code 6 : Literal String Field
Item 2: Output Message(s) 1
Item 3: Field Name <D><A>SITE<20>1
>
10.6.6. Setting Up A Data Output Record To Transmit And/Or Log Data
Four Line Items must be set in a Data Output Record when you plan to transmit data in an output message
and/or log data in ZENO
®
-3200 memory:
Line Item #1: Field Type Code
Line Item #4: Input Record
Line Item #5: Field Decimal Places
Line Item #6: Field Width
Line Item #7: Data Storage Class Code (used ONLY when logging data)
Setting The Field Type Code, Line Item #1
The following questions will assist you in deciding what type of Field Type Code is needed:
1. Will you have more than one output message?
If you need different data in different output messages but in the same field, you need to use Field
Type Code #15.
Otherwise, proceed with question #2.
If you use Field Type Code #15, data specified in Line Items #4, #8, #9 and
#10 must be of the same type--all floating-point, long integer or string data
values.
2. Do you need the ZENO
®
-3200 to transmit the data value automatically?
If yes, proceed with question #3.
If no, go question #7.
3. Is the data going to a GOES transmitter?
If you need GOES binary data, use Field Type Code #12.
If you also need the data logged and/or transmitted in another output message, create a separate
Data Output Record and proceed to question #5.
4. Is the data going to an ARGOS transmitter?