ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page F-14
GETREPEATnnn,
Retrieve the value of the
nnn
th
eight remote addresses from the ZENO
®
-3200.
ZENOSOFT
®
will respond with a CCSAIL ERROR 6 if REPEAT line nnn is not valid. (Currently, 1 is
the only valid number.)
If it is a valid REPEAT line number, ZENOSOFT
®
will respond with the string REPEATnnn, followed
by a comma-separated list of remote addresses. for example, if ZENO
®
-3200 number 329 is being polled
for the current repeater values, after they were set as described in the previous paragraph, the
communications would be as follows:
#80010001GETREPEAT1,60^C
#00018001
REPEAT1 1001 1002 1003 -1 -1 -1 -1 -1,43^C
10.4. Data Collection Control
ENDSAMPLE
This command instructs the remote ZENO
®
-3200 to cease sampling. This command is equivalent to
entering the Zeno Program Menu through the standard User Interface, in that it allows the user to
construct temporarily inconsistent configurations. (For example, if the user wishes to rewrite a General
Serial Interface script, intermediate stages in the construction of the script may not make up a valid script
file.)
The ZENO
®
-3200 will not start sampling again until the user sends the STARTSAMPLE command.
There is one exception to this, which already occurs when the user enters the Zeno Program Menu
through the standard User Interface. If the user is communicating with the ZENO
®
-3200 over a telephone
modem, and the Carrier Detect line is dropped, then the ZENO
®
-3200 assumes that the connection has
been lost. If the ZENO
®
-3200 has a valid configuration at this stage, then it quits the ZENO
®
-3200
Program Menu and starts sampling again.
If the user enters the User Interface while the ZENO
®
-3200 is not sampling––using either the U command
or the CCSAIL
OPEN command––the user will be presented with the Zeno Program Menu, rather than
with the User Menu.
The
ENDSAMPLE command must be used before any of the commands relating to GSI scripts, sensors,
processes, or data output items can be used. Further, several run-time parameters can only be modified
after the
ENDSAMPLE command has been used; please refer to Appendix F, section 10.1.
For example, to instruct ZENO
®
-3200 number 1234 to cease sampling temporarily, the following
command would be sent: