ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-5
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code = 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) = 1 DEFAULT
Item 3: Field Name = bp
c3/bp
Item 4: Data Process Record = P1.1
4
c4/P1.1
4
Item 5: Field Decimal Places = 0
c5/0
Item 6: Field Width = 4
c6/4
Item 7: Data Storage Class Code = 7 : Compressed Floating Point (2)
c7/7
DEFAULT = Default Data: it is not necessary to enter a command for this Item.
4 This data will vary depending on the number of sensors being connected to the ZENO
-3200.
4. 20MA CURRENT LOOP
SENSOR MENU
ITEM DATA
COMMAND ENTERED
Item 1: Sensor Type code = 3
c1/3
Item 2: Sensor Name = current
c2/current
Item 3: Sensor Input Channel = 1
c3/1
Item 4: Analog Channel Gain = 1 DEFAULT
Item 5: Analog Channel Attenuation = 1 DEFAULT
Item 6: Switched Power code = 0
1
DEFAULT
1
Item 7: Sensor Excitation Voltage = 0 DEFAULT
Item 8: Switched Excitation Return Code = 0 DEFAULT
Item 9: Sensor Warm up Time = 0 DEFAULT
Item 10: Sensor Sample Count = 1 DEFAULT
Item 11: Maximum Sensor Readings = 0 DEFAULT
Item 12: Sensor Timing Loop = 2
c12/2
Item 13: Conversion Coefficient A = 0 DEFAULT
Item 14: Conversion Coefficient B = 40
2
c14/40
2
Item 15: Conversion Coefficient C = 0 DEFAULT
Item 16: Retry Count = N/A N/A
DEFAULT = Default Data, it is not necessary to enter a command for this Item.
1 Switched power at 5V or 12V is probably needed for these sensors.
2 Gives result in mA for nominal 25.0 resistor. for maximum accuracy, use value of 1000/R where R is the
measured resistance of the current sense resistor from the resistor calibration data.