ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page F-21
#00015310ERROR61,56^C
#53100001SETDATA14,9 1 "AWSPD" P1.11 1 5 7,50^C
#00015310OK,92^C
GETSENSORnnn,
GETPROCESSnnn,
GETDATAnnn,
These commands work in essentially the same way (and in a similar way to the GETGSI command). The
remote ZENO
®
-3200 returns the value of sensor record number nnn, process record number nnn, or
data output record number
nnn. These commands can be used while the remote ZENO
®
-3200 is still
sampling – the
ENDSAMPLE command does not need to be used first.
If the specified record exists, the remote ZENO
®
-3200 returns with SENSORnnn, PROCESSnnn, or
DATAnnn, followed by the specified line. The initial word SENSOR, PROCESS or DATA is omitted.
If record number
nnn does not exist, ZENOSOFT
®
will respond with a CCSAIL ERROR 16.
For example, if the user wishes to double-check that data output record number 14 was correctly received
by the remote ZENO
®
-3200 in the previous example, the following conversation would occur.
#53100001GETDATA1458^C
#00015310
DATA14,9 1 "AWSPD" P1.11 1 5 7,52^C
DELSENSORnnn,
DELPROCESSnnn,
DELDATAnnn,
These commands work in essentially the same way (and in a similar way to the DELGSI command).
They instruct the remote ZENO
®
-3200 to delete the specified sensor, process or data output record. If
nnn takes the value 0, then all sensors, processes, or data output records are deleted.