ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-17
Settings for Wind Direction/Wind Speed
ITEM DATA
COMMAND ENTERED
Item 1: Process Category Code 2 : Environmental
C1/2
Item 2: Process Type code 1 : Wind Vector Average DEFAULT
Item 3: User-defined Process Name = 3: AvgWind
c3/AvgWind
Item 4: Input for Wind Speed S2 : wndspd
2
C4/S2
2
Item 5: Input for Wind Direction S1 : wnddir
2
C5/S1
2
Item 6: Input for Compass
S0.1 (Not specified)
3
DEFAULT
DEFAULT = Default value: it is not necessary to enter a command for this item.
2 This data will vary depending on the number of sensors being connected to the ZENO
-3200.
3 If a serial compass is included, specify the output from the Sensor Record specifying the compass. Also, Line
Items #5 and #6 from the System Functions Menu will need to be specified (refer to Section 5.7).
DATA OUTPUT MENU
Settings for Average Wind Speed
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code = 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) = 1 DEFAULT
Item 3: Field Name = WS
c3/WS
Item 4: Data Process Record = P1.1
4
c4/P1.1
4
Item 5: Field Decimal Places = 1
c5/1
Item 6: Field Width = 5
c6/5
Item 7: Data Storage Class Code = 7 : Compressed Floating Point (2)
c7/7
DEFAULT = Default value: it is not necessary to enter a command for this item.
4 This value will vary depending on the number of sensors being connected to the ZENO
-3200. Further, if you
want scalar average wind speed instead of vector average wind speed, use data output #3; i.e., P1.3.
Settings for Average Wind Direction
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code = 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) = 1 DEFAULT
Item 3: Field Name = WD
c3/WD
Item 4: Data Process Record = P1.2
5
c4/P1.2
5
Item 5: Field Decimal Places = 0 DEFAULT
Item 6: Field Width = 4
c6/4
Item 7: Data Storage Class Code = 7 : Compressed Floating Point (2)
c7/7
DEFAULT = Default value: it is not necessary to enter a command for this item.
5 This value will vary depending on the number of sensors being connected to the ZENO
-3200. Further, if you
want independent wind vector average instead of component wind vector average, use data output #12; i.e.,
P1.12.