ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 134
TEST MENU
(Rx,y) Display Sensors x-y RAW Data (Ex) Display Sensor x Error Codes
(Sx,y) Display Sensors x-y SCALED Data (P) SDI-12 Pass-Through Mode
(Cx) Calibrate Sensor Record x (U) User Menu
(Vx) View Process Record x (Q) Quit
(D) View Data Collection Counters (H) Help
(B) Display BIT Status
> C3
Sensor Name: VANE
Conversion Coefficient A: 0
Enter new Conversion Coefficient A: 0
Conversion Coefficient B: 142
Enter new Conversion Coefficient B: 142
Conversion Coefficient C: 0
Enter new Conversion Coefficient C: 0
7.3. VIEWING PROCESS RECORD DATA
Option Vx in the Test Menu allows you to view the current values being outputted by Process Record
Number x. It operates essentially the same as typing help option HPx.
161
The information that you will see is as follows:
the type of process (e.g., averaging)
the definition of each output from the process (e.g., the mean and standard deviation)
the latest value of each output
Values outputted by the Test Menu are updated only while the sensor is
actually sampling. Hence, whenever a change is made that causes the
ZENO
®
-3200 data collection to restart, any values outputted by the Test
Menu are not updated until the beginning of next Sample Interval.
7.4. VIEWING SENSOR ERROR & STATUS CODES
Option Ex in the Test Menu allows you to view the current error & status codes for Sensor Record
Number x.
It is unlikely that you will use this option.
162
Three values are displayed:
161
Refer to Section 2.4.2.
162
This is primarily for personnel at Coastal Environmental Systems (CES).