ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-25
COMMANDS TO ENTER
I1 C1/STRING 1 ( 50 )
I2 C2/SEND "\B "
I3 C3/WAIT 75
I4 C4/SEND "%1sXH1!", sID
I5 C5/RECEIVE 500, "%s", S1
I6 C6/SEND "\B "
I7 C7/WAIT 75
I8 C8/SEND "%1sXU1!", sID
I9 C9/RECEIVE 500, "%s", S1
I10 C10/SEND "\B "
I11 C11/WAIT 75
I12 C12/SEND "%1sXQ1;3.3;3;0005!", sID
I13 C13/RECEIVE 500, "%s", S1
MEMORY MANAGEMENT MENU
ITEM DATA
COMMAND ENTERED
Item 1: COM1 GSI Memory Size in Bytes = 0 DEFAULT
Item 2: COM2 GSI Memory Size in Bytes = 100 C1/100
Item 3: COM3 GSI Memory Size in Bytes = 0 DEFAULT
DEFAULT = Default value: it is not necessary to enter a command for this item.
PROCESS MENU
Settings to Initialize Vaisala 425AH Sensor on COM2
ITEM DATA
COMMAND ENTERED
Item 1: Process Category Code = 3 : Alarm
C1/3
Item 2: Process Type code = 8 : Missing Sensor Data Process
C2/8
Item 3: User-defined Process Name = 3 : Miss425
c3/Miss425
Item 4: Input for Sensor Data S1.1 : 425AH
4
C4/S1.1
4
Item 5: Default Data 0 DEFAULT
Item 6: Digital Output Channel 0 DEFAULT
DEFAULT = Default value: it is not necessary to enter a command for this item.
4 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
ITEM DATA
COMMAND ENTERED
Item 1: Process Category Code = 3 : Alarm
C1/3
Item 2: Process Type code = 12 : Previous Sample Data Process
C2/12
Item 3: User-defined Process Name = 3 : Prev
c3/Prev
Item 4: Input for Data = P1.1 : Miss425
5
C4/P1.1
5
DEFAULT = Default value: it is not necessary to enter a command for this item.
5 This value will vary depending on the number of sensors being connected to the ZENO
-3200.