6.7.7. Connecting A GOES Radio and Serial Sensors To The Same COM Port
You may wish to attach both a GOES radio and one or more serial sensors to the ZENO. This can be
done as long as the serial sensor(s) is not connected to the same line as the GOES radio. In the case of the
Telonics TGT-1 transmitter, the RS232, RS485 and Compass ports are available for serial sensor use. In
the case of the Campbell Scientific SAT HDR GOES transmitter, the TTL, RS485 and Compass ports are
available for serial sensor use.
6.7.8. GOES Transmitter Diagnostics
You can obtain basic diagnostic information on the state of the Telonics TGT-1 or Campbell Scientific
SAT HDR GOES transmitter by entering D from the GOES Menu. The ZENO
®
-3200 displays the
diagnostic information in a simple-to-read table.
6.7.9. Self-Timed Transmissions
Once you have set up the GOES parameters, the only additional step for self-timed transmissions is to
define a data output message to be transmitted over the COM2 port. Refer to Section 10.6 for details on
creating an output message. The output message can contain normal ASCII characters, or it can be in
binary format as described in Section 6.7.11. All output messages sent to COM2 will be buffered up by
the GOES transmitter and transmitted during its self-timed transmit window.
6.7.10. Random Transmissions
To generate random or emergency transmissions, you must perform the following steps:
Set up a data output message to contain the data to be transmitted when the alarm message occurs.
128
This can be a normal ASCII message, or it can be in the binary format described below.
In the Output Message Timing Menu, specify that the message is to be routed to COM2, and assign
the message a period of zero.
129
In the Process Menu, set up a Dial-out Alarm Process to trigger the alarm message under the desired
circumstances.
130
Whenever the sensor or process input moves beyond the defined threshold level, a random transmission is
initiated. For example, by setting the sensor or process input to be a water level measurement, and by
setting the alarm threshold to a specified level, a random transmission can be initiated whenever the water
level reaches the specified value.
6.7.11. GOES Binary Format
The GOES binary format packs data into an efficient format that is suitable for transmission over a GOES
satellite (or other limited communications channel).
128
Refer to Section 11.2.
129
This will indicate that the message is not transmitted as a regular output message. Refer to Section 11.3.
130
Refer to Section 11.3.