ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 17
DATA RETRIEVAL MENU
(A) Show Records AFTER Specified Time (F) Flash Memory Information
(B) Show Records BETWEEN Timespan (D) Delete All Data Records
(Ln) Show LAST n Records (N) Number of Records Logged
(*) Show ALL Data Records (U) User Menu
(@n) Show n Unmarked Records (Q) Quit
(M) Mark Recently Shown Data (H) Help
(C) Compute Data Logging Capacity
Precede Any "Show Data" Command With An 'X' for X-Modem Transfer
(e.g. Enter 'X*' To Send All Data Sets Via X-Modem)
> L4
Hit The Space Bar To Halt The Log Data Output.
DATE TIME AvgTemp AvgBatt
01/07/11 15:02:55 24.1 13.8
01/07/11 15:03:55 24.2 13.8
01/07/11 15:04:55 24.2 13.8
01/07/11 15:05:55 24.1 13.8
When you are done looking at the logged data, you can quit the User Interface by typing Q{ENTER} to
QUIT (exit).
Section 4 provides comprehensive information about viewing logged Data Records.
3.1.2. Changing Output Message Format
If your computer is not connected to the ZENO
®
-3200, connect your ZENO
®
-3200 to your computer and
apply power.
16
After you see the boot-up message from the ZENO
®
-3200, type U{ENTER} in your
terminal emulation program to obtain the User Menu.
There are three types of message formats available from the ZENO
®
-3200:
Comma delimited
Space delimited
CCSAIL format (comma delimited with CCSAIL addressing)
17
If you want to change the format of a message, you can do so with absolutely no disruption in ZENO
®
-
3200 data collection. From the User Menu, type the command F{ENTER} to enter the System Functions
Menu. You will see the following screen.
16
Refer to Section 2.2.
17
Details about the CCSAIL protocol are discussed in Section 4.6.