Campbell SAT ARGOS Manual de usuario Pagina 378

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 394
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 377
ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page F-20
placed after record number mmm. If n is B, the new record is placed before record number mmm. Upon
success, another record will have been added in the desired location and ZENOSOFT
®
will return a
CCSAIL
OK.
If CCSAIL
ENDSAMPLE has not been previously sent, ZENOSOFT
®
responds with a CCSAIL ERROR
8.
If
n is neither an A or B, ZENOSOFT
®
will respond with a CCSAIL ERROR 12.
If record number
mmm does not exist, ZENOSOFT
®
will respond with a CCSAIL ERROR 16.
If no more records can be created, ZENOSOFT
®
will respond with a CCSAIL ERROR 60.
SETSENSORnnn,abcde,
SETPROCESSnnn,abcde,
SETDATAnnn,abcde,
These commands work essentially the same way (and in a similar way) to the SETGSI command.
The commands change sensor, process or data output record number
nnn to take the value abcde. The
value
abcde is formatted just as the corresponding line would be formatted in a complete configuration
file, except that the initial word
SENSOR, PROCESS or DATA is omitted.
If record number
nnn does not exist, but record number nnn-1 exists, the ZENO
®
-3200 creates record
nnn and changes it to the new value abcde.
The
ENDSAMPLE command must be used before any of these commands are used.
If the specified record can be written, the ZENO
®
-3200 writes that record and returns a CCSAIL OK
message.
If CCSAIL
ENDSAMPLE has not been previously sent, ZENOSOFT
®
responds with a CCSAIL ERROR
8.
If record number
nnn–1 does not exist, ZENOSOFT
®
will respond with a CCSAIL ERROR 16.
If no more records can be created, ZENOSOFT
®
will respond with a CCSAIL ERROR 60.
If there is an error in the abcde string, ZENOSOFT
®
will respond with a CCSAIL ERROR 61.
For example, in the following conversation, the user first attempts to set up data output record number 14,
referring to a nonexistent sensor output (the 11
th
output from sensor number 1: S1.11). The user then sets
up the correct data output record, referring to the 11
th
output from process number 1: P1.11. The unit ID
number of the ZENO
®
-3200 is 5310.
#53100001SETDATA14,9 1 "AWSPD" S1.11 1 5 7,53^C