Fig. 11 Setting Range of Sensor Voltage
The wiring diagram labeled “Full Bridge” represents the pressure transducer. The
pressure transducer has four prongs. On the bottom of the transducer these prongs are
numbered, note that the numerals are very small. Prong one will connect to the “Excite”
wire which is then connected to port E1 of the data logger. Prong two will connect to the
“High” wire which is then connected to port 1H. Prong 3 is connected to the “Ground”
wire which is then connected to port AG. Prong 4 is connected to the “Low” wire which
is then connected to port 1L. “Shield” is the bare wire in the cable bundle and is
connected to port G. It is set up so that:
Prong 1—Red Wire—Port E1
Prong 2—White Wire—Port 1H
Prong 3—Black Wire—Port AG
Prong 4—Green Wire—Port 1L
Press the “Sensors” button in the window of Fig. 12 and the “home” button in the
window of Fig. 10. You should be back now to the main menu (Fig. 1).