Appendix H. Adding Direct or P190 Router to RF400 Network
H-3
Router RF400 Configuration
Configure the RF400s’ Active Interfaces to CSDC 7 (defaults to 7).
Configure the RF400’s Standby Mode to the Standby Mode setting that
CR10XPB_1’s RF400 and the CR205s use.
Configure CR510PB_2’s RF400 net address, radio address, and hopping
sequence the same as the network’s.
Antenna Height and Location
Arrange the router antenna’s height and/or position so that it has a good
‘view’ of the antennas of both the ‘toward LoggerNet’ and the ‘toward
destination’ stations (height is everything in rf links).
CR10XPB_1
(P190)
|
RF400 Series
CSDC 7
CR205_3
CR205_4
PC
(LoggerNet)
|
RF400 Series
AutoSense
CR510PB_2
|
RF400 Series
CSDC 7
A
DDED
ROUTER
It is possible to similarly add a router to a P193 path to remote.