G-1
Appendix G. Phone to CR205s Network
In this configuration LoggerNet does direct 15 minute scheduled collections of
5 remote CR205s (may be other rf CR200 Series). This approach results in the
greatest number of files collected from the remotes (as compared to the P190
or P193 approach).
There is no beaconing in this configuration. LoggerNet needs no beacon as it
can discover CR205s using the static routes created by the device map. When
LoggerNet is first run, it will be unaware of the CR205s, but at the first
connection of each CR205 they will exchange hellos and become neighbors.
LoggerNet will keep the CR205s as neighbors until LoggerNet is closed or its
router is reset.
The COM210, PS100 with A100 and RF400 are not a PakBus node but merely
a transparent connection for LoggerNet to talk, as though directly, to the
CR205s.
Hardware Setup
PC
LoggerNet
modem
COM210
CR205_2
CR205_3
CR205_1
CR205_4
CR205_5
RF400
COM2xx to RF400
PS100
&
A100
null-modem
LoggerNet Device Map
ComPort_1
PhoneBase
PhoneRemote
PakBusPort
CR200_1 (PakBus Address = 1)
CR200_2 (PakBus Address = 2)
CR200_3 (PakBus Address = 3)
CR200_4 (PakBus Address = 4)
CR200_5 (PakBus Address = 5)
After once dialing up and connecting in LoggerNet, PakBusGraph will display
the CR205 neighbors.