Campbell 21X Especificaciones Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
Number 4250-2010
Revision 0.1
Date MAY 1996
Page 23 of 37
Enter M to select DCP channel 01. The display message will be "P
CHANNEL 01."
Enter N to edit the sensor configuration. The display message will
be "P01 SENSOR TYPE 10."
Enter V to scroll through the sensor configuration until you reach
the "start of measurement prompt", "P01 START OF MEAS
23:30:00."
The start of measurement time should be programmed for 30
minutes after the current hour (e.g., if the current time is 17:04:29,
enter 17:30:00). A second prompt asking "CHANGE ALL
CHANNELS? (1=Y, 2=N) will be displayed.
Enter 1, setting the start of measurement time for all channels to
17:30:00. The display message will be "P01 START OF MEAS
17:30:00."
This completes programming of the Handar 540A/570A DCP.
4.4 PRE-FIELD PERFORMANCE TESTING
Pre-field performance testing of the Handar 540A/570A DCP includes laboratory
performance testing and a 7-day field test at the Fort Collins Transmissometer Calibration and
Test Facility. Laboratory performance testing verifies proper programming and calibration of the
DCP. Field testing exposes the DCP to a varying operational environment, testing the ability of
the DCP to maintain accurate timing and calibration over a wide range of operating conditions.
Document all performance checks and results on the Laboratory Performance Testing Form -
Handar 540A/570A DCP (see Figure 4-10).
4.4.1 General Information
RECORD Record the DCP serial number, the site it was received from, and
GENERAL the date it was received. The initials of the technician performing
INFORMATION the inspection should also be recorded.
IDENTIFY Identify the DCP model (Figure 4-2 shows the front panel layout
DCP MODEL of each of the three DCP models used by ARS).
4.4.2 Laboratory Performance Testing
Laboratory performance testing repeats the DCP performance and timing checks and the
transmission test performed during the post-field inspection and performance checks. It also
adds a run mode timing check. Procedures for conducting laboratory performance testing are:
Perform DCP timing checks as described in Section 4.1.4.
Perform DCP A/D converter checks as described in Section 4.1.5.
Perform the DCP transmission test as described in Section 4.1.6.