Number 4250-2010
Revision 0.1
Date MAY 1996
Page 13 of 37
COMPARE The DCP data channel 04 reading (Rotronics AT output signal)
READINGS must be adjusted by subtracting 100 from the reading obtained
during the test. Compare this adjusted reading with the temperature
measurement obtained with the hand held sensor. The two values
should then match within ± 2 F
°
.
Compare the DCP data channel 05 reading (Rotronics RH output
signal) with the RH measurement obtained with the hand held
sensor. The two values should agree within ± 3%.
Compare the DCP data channel 10 reading (DCP internal battery
voltage) with the internal battery voltage measured during the DCP
internal physical inspection. The two values should agree within ±
0.005 volts.
4.1.6 Transmission Test
CONNECT Connect an RF wattmeter (with a 200-500 mHz, 25-watt power
WATTMETER element) to the "RF Output" connector located on the front panel of
the DCP. A 50 Ohm, 25-watt load resistor should be connected to
the output of the wattmeter.
SET CHANNEL Set the GOES primary channel select switches to the channel
SWITCHES number assigned to the ID programmed for the DCP under test.
INITIATE With the DCP in "PROGRAM" mode, initiate a transmission by
TRANSMISSION entering #.
RECORD The wattmeter should read 10 ± 2 watts. Record the observed
READING reading on the Post-Field Inspection Checklist - Handar 540A/570A
DCP (Figure 4-1).
RESET Reset the GOES primary channel select switches to 900.
SWITCHES
4.2 ROUTINE LABORATORY SERVICING
Record and document all information and procedures on the Routine Servicing Checklist -
Handar 540A/570A DCP (Figure 4-7).
RECORD Record the DCP serial number, the site it was received from, and
GENERAL the date it was received. The initials of the technician performing
INFORMATION the inspection should also be recorded.
IDENTIFY Identify the DCP model (Figure 4-2 shows the front panel layout
DCP MODEL of each of the three DCP models used by ARS).
NOTE REASON Note whether the DCP was returned for annual servicing (no
FOR RETURN observed operational problems in the field) or for unscheduled
maintenance (unit malfunctioning). If returned for unscheduled
maintenance, describe the observed field symptoms.