Number 4250-2010
Revision 0.1
Date MAY 1996
Page 6 of 37
4.1.2 Physical Inspection - External
INSPECT Inspect the outside of the DCP case thoroughly. Look for signs of
CASE external damage (dented, scraped, or gouged surfaces). Examine the
latches and external connectors. Describe any damage or general
deterioration noted.
RECORD If the DCP is a model 570A, step through the display, recording
DISPLAY the readings displayed for each channel.
INSPECT Open the cover on the DCP and inspect the seal between the cover
SEAL and the case. Look for loose sections of seal, tears, and worn spots.
4.1.3 Physical Inspection - Internal
NOTE POWER Note whether the power switch is "ON" or "OFF" (see Figure 4-3
for switch location).
NOTE CHANNEL Note the settings of the GOES primary channel (#1) and secondary
SETTINGS channel (#2) switches (see Figure 4-3 for switch locations). The
GOES primary channel selection switch should be set to "900"
(inhibits transmission). The GOES secondary channel selection
switch should be set to "000" (channel unused). If the switches are
not set properly, they should be reset to these channel numbers
before proceeding with this inspection.
INSPECT DCP Inspect the interior of the DCP, checking that all circuit boards are
INTERIOR firmly seated, all hold-down brackets are in place and secure, and all
cables and connectors are undamaged and in place. Describe any
improper conditions.
MEASURE Measure the internal battery voltage. If it is less than 11.8 volts,
BATTERY connect a current limited power supply set at 16 volts and 500 ma
VOLTAGE to the DCP Solar Panel/Battery Charger input for a period of 24
hours. If the battery voltage does not reach a minimum voltage of
13.8 volts, it must be replaced during servicing.
CHECK Check the installation date on the battery. If the battery is more
INSTALLATION than 5 years old, it must be replaced during servicing, regardless
DATE of the battery's state of charge.
4.1.4 DCP Timing Checks
PROGRAM NOTE! If the DCP power switch was off, or has been MEMORY
turned off for any reason, the program and timing will have been
lost from the DCP memory and this section of the post-field
inspection should be omitted.
EXECUTE Execute the Handar DCP communications program "TERM" from
PROGRAM the IBM PC-compatible computer.