SECTION 3. INSTRUCTION SET BASICS
3-10
TABLE 3.9-3. Output Instruction Memory and Execution Times R = No. of Reps.
INTER. MEM. FINAL PROG. EXECUTION TIME (ms)
INSTRUCTION LOC.
VALUES
1
BYTES FLAG 0 LOW FLAG 0 HIGH
69 WIND VECTOR 2+9R (2, 3, or 4)R 12
Options 00, 01, 02 4.0 + 17.4R 3.3 + 70.7R
Options 10, 11, 12 3.0 + 16.3R 4.0 + 75R
70 SAMPLE 0 R 6 0.2 0.5+ 0.4R
71 AVERAGE 1+R R 7 0.6+ 1.1R 1.5+ 4.4R
72 TOTALIZE R R 7 0.6+ 1.0R 1.0+ 1.7R
73 MAXIMIZE (1 or 2)R (1,2, or 3)R 8 1.0+ 1.2R 5.0+ 3.0R
74 MINIMIZE (1 or 2)R (1,2, or 3)R 8 0.8+ 1.2R 5.0+ 3.0R
75 HISTOGRAM 1+binsRbinsR 24 0.8+ 3.4R 1.6+ 5.2 + (1.4 bins)R
77 REAL TIME 0 1 to 4 4 0.2 3.8
78 RESOLUTION 0 0 3 0.4 0.4
79 SMPL ON MM R R 7 0.4 1.7 + 1.1R
80 STORE AREA
1
00 70.3 0.3
82 STD. DEV. 1+3R R 7 1.5+ 2.0R 2.9+ 2.1R
1
Output values may be sent to either Final Storage area or Input Storage with Instruction 80.
TABLE 3.9-4. Program Control Instruction Memory and Execution Times
MEMORY
INTER. PROG.
INSTRUCTION LOC. BYTES EXECUTION TIME (ms)
83 IF CASE <F 0 10 0.5
85 LABEL SUBR. 0 3 0
86 DO 0 6 0.3
87 LOOP 1 10 0.3
88 IF X<=>Y 0 11 0.8
89 IF X<=>F 0 13 0.6
90 LOOP INDEX 0 3 0.7
91 IF FLAG/PORT 0 7 0.4
92 IF TIME 1 12 0.4
93 BEGIN CASE 1 8 0.3
94 ELSE 0 4 0.2
95 END 0 4 0.2
96 SERIAL OUT 0 3 Option: 0x 1x 2x 3x
Time: 0.4 1.8 2.1 0.9
Option: 4x 5x 6x 7x
Time: 1.7 1.9 0.7 0.5
97 INIT.TELE. 7 17 2.3
120 GOES SAT 0 or 2 5 8000
121 ARGOS SAT 0 8 250