CMP3-L Pyranometer
Revision: 2/09
Copyright © 2006-2009
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - CMP3-L Pyranometer

CMP3-L PyranometerRevision: 2/09Copyright © 2006-2009Campbell Scientific, Inc.

Pagina 2 - Warranty and Assistance

CMP3-L Pyranometer Select the input range as follows: 1. Estimate the maximum expected input voltage by multiplying the maximum expected irradiance (

Pagina 3

CMP3-L Pyranometer 5.4 Example Programs The following programs measure the CMP3-L every 10 seconds and convert the mV output to Wm-2 and MJm-2. A se

Pagina 4

CMP3-L Pyranometer VoltDiff(Solar_Wm2,1,mV25,1,True,0,_60Hz,66.577896,0) ‘use the 50 mV range for the CR3000, CR5000 and CR9000 '

Pagina 5

CMP3-L Pyranometer 6: If time is (P92) 1: 0 Minutes (Seconds --) into a 2: 60 Interval (same units as above) 3: 10 Set Output Flag

Pagina 6 - 3. Installation

CMP3-L Pyranometer Solution 1 – Change the multiplier in the instruction to (m*0.0001). This will totalize MJ m-2 instead of kJ m-2. Solution 2 – Rec

Pagina 7

CMP3-L Pyranometer into the sensor or enclosure connectors. If the resistance is infinite, there is a broken connection (check the wiring). 4. Dis

Pagina 8 - 4. Wiring

CMP3-L Pyranometer 12

Pagina 9 - 5. Example Programs

This is a blank page.

Pagina 10 - 5.3 Offset

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Pagina 11 - 5.4 Example Programs

Warranty and Assistance The CMP3-L PYRANOMETER is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under no

Pagina 12 - 5.4.2 CR10X Example Program

CMP3-L Pyranometer Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® book

Pagina 14 - 7. Troubleshooting

CMP3-L Pyranometer 1. General Description This manual provides information for interfacing the CMP3-L Pyranometer to various models of Campbell Scien

Pagina 15

CMP3-L Pyranometer Temperature Dependence of sensitivity: + 5% (-10º to + 40ºC) Tilt response (+80º) (at 1000 W/m2): < + 2% OTHER SPECIFICATIONS

Pagina 16

CMP3-L Pyranometer Tools required for installation on a tripod or tower: Small and medium Phillips screwdrivers 5/16”, 1/2” open end wrenches 5/32” Al

Pagina 17 - This is a blank page

CMP3-L Pyranometer 4. Wiring A schematic diagram of the CMP3-L is shown in Figure 4-1. Red Blue Black White BlackShieldFIGURE 4-1. CMP3-L Schem

Pagina 18

CMP3-L Pyranometer TABLE 4-2. Single-Ended Connections to Campbell Scientific Dataloggers Color Description CR9000(X) CR5000 CR3000 CR1000