Campbell cs215 Manual de instrucciones

Busca en linea o descarga Manual de instrucciones para De medición, control y control Campbell cs215. Campbell cs215 Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL CS215 Temperature and Relative Humidity Probe Revision: 8/14 Copyright © 2005- 2014 Campbell Scientific

Pagina 2

Table of Contents iv

Pagina 3 - Limited Warranty

CS215 Temperature and Relative Humidity Probe 1. Introduction The CS215 Temperature and Relative Humidity Probe is designed for general meteorologic

Pagina 4 - Assistance

CS215 Temperature and Relative Humidity Probe 4. Quickstart Short Cut is an easy way to program your datalogger to measure the CS215 sensor and assig

Pagina 5 - Precautions

CS215 Temperature and Relative Humidity Probe 5. Under the Available Sensors and Devices list, select the Sensors | Meteorological | Relative Humidit

Pagina 6

CS215 Temperature and Relative Humidity Probe 8. If LoggerNet, PC400, RTDAQ, or PC200W is running on your PC, and the PC to datalogger connection is

Pagina 7

CS215 Temperature and Relative Humidity Probe Filter Material: Sintered high-density polyethylene, average pore size 13 µm EMC Compliance: Tested an

Pagina 8

CS215 Temperature and Relative Humidity Probe 7.1 Wiring to Datalogger TABLE 7-1. Datalogger Wiring Terminal Terminal number Function CR800, CR850

Pagina 9

CS215 Temperature and Relative Humidity Probe A Short Cut tutorial is available in Section 4, Quickstart. If you wish to import Short Cut code into e

Pagina 10 - Table of Contents

CS215 Temperature and Relative Humidity Probe 7.3 Installation Locate the sensor over an open, level area at least 9 m (EPA) in diameter. The surfac

Pagina 11 - Humidity Probe

CS215 Temperature and Relative Humidity Probe 4. Tighten the collar until it securely grips the probe. 5. Attach the radiation shield to the tripod

Pagina 13

CS215 Temperature and Relative Humidity Probe 8. Operation 8.1 Sensor Measurements CRBasic instruction SDI12Recorder() measures the CS215 sensor usi

Pagina 14 - 6. Specifications

CS215 Temperature and Relative Humidity Probe 8.1.1.2 Edlog Dataloggers The aM! command takes about 700 milliseconds in total to make a measurement f

Pagina 15 - 7. Installation

CS215 Temperature and Relative Humidity Probe 8.1.3 Power Conservation The CS215 draws less than 70 µA of current between measurements. In most appl

Pagina 16 - 7.2 Datalogger Programming

CS215 Temperature and Relative Humidity Probe 9.2 Maintenance The CS215 probe requires minimal maintenance. • Check the radiation shield monthly to

Pagina 17 - 7.2.2 Edlog Programming

CS215 Temperature and Relative Humidity Probe • There are eight holes in the socket, while the element only has four pins. • The element will work w

Pagina 18 - 7.3 Installation

CS215 Temperature and Relative Humidity Probe Sensorconnectorsticking out ofthe end of thetubeGold pinsSensingElementSensing part ofthe element.Printi

Pagina 19

CS215 Temperature and Relative Humidity Probe Sensing part ofelement NOT onthe center lineCenter line of thesensor body FIGURE 9-2. Incorrect fit of

Pagina 20 - 8. Operation

CS215 Temperature and Relative Humidity Probe Meyer, S. J. and K. G. Hubbard, 1992: Nonfederal Automated Weather Stations and Networks in the United S

Pagina 21 - 8.1.2 Long Cables

CS215 Temperature and Relative Humidity Probe 18

Pagina 22 - 9.1 Troubleshooting

Appendix A. Importing Short Cut Code Into CRBasic Editor This tutorial shows: • How to import a Short Cut program into a program editor for additio

Pagina 23 - 9.3 Calibration

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Pagina 24

Appendix A. Importing Short Cut Code Into CRBasic Editor 5. The program can now be edited, saved, and sent to the datalogger. 6. Import wiring info

Pagina 25

Appendix B. Example Programs B.1 CRBasic Programs B.1.1 Example CR200(X) Program This example program shows the measurement of a single CS215 and

Pagina 26 - Center line of the

Appendix B. Example Programs B.1.2 Example Program for CR800, CR850, CR1000, CR3000, or CR5000 This program can be used directly with CR800 series,

Pagina 27

Appendix B. Example Programs B.2 Edlog Program The following example is written for the CR10(X). Programs for the CR500, CR510, and CR23X would be

Pagina 28

Appendix B. Example Programs B-4

Pagina 29 - Into CRBasic Editor

Appendix C. Environmental Performance This appendix details tests and limitations of the sensor when exposed to extremes of the environment. C.1 Te

Pagina 30 - A.1.2 Edlog

Appendix C. Environmental Performance C.3 Operating Range of RH Element The RH sensor is specified to work over the entire humidity range of 0 to 10

Pagina 31 - B.1 CRBasic Programs

Appendix D. SDI-12 Sensor Support D.1 SDI-12 Command Basics SDI-12 commands have three components: Sensor address (a) – a single character, and i

Pagina 32 - CR5000 dataloggers

Appendix D. SDI-12 Sensor Support D.1.1 Address Query Command (?!) Command ?! requests the address of the connected sensor. The sensor replies to t

Pagina 33 - B.2 Edlog Program

Appendix D. SDI-12 Sensor Support The terminal emulator is accessed by navigating to the Datalogger menu in PC200W, the Tools menu in PC400, or the D

Pagina 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 35 - Performance

Appendix D. SDI-12 Sensor Support D.2.2 CR1000 Datalogger Example 1. Connect a CS215 to the CR1000 (see TABLE 7-1). 2. In the LoggerNet Connect s

Pagina 36 - C.4 Measurement Below 0 °C

Appendix D. SDI-12 Sensor Support D.2.3 CR10X Datalogger Example 1. Connect CS215 to the CR10(X) (see TABLE 7-1). 2. Download a datalogger program

Pagina 37 - D.1 SDI-12 Command Basics

Appendix D. SDI-12 Sensor Support D-6

Pagina 39

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Pagina 40

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Pagina 42

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Pagina 43

Table of Contents Appendices A. Importing Short Cut Code Into CRBasic Editor ... A-1 A.1 Importing Short Cut Code into a Program Editor ...

Pagina 44

Table of Contents Tables 7-1. Datalogger Wiring.................... 6 C-1. Environmental

Comentarios a estos manuales

Sin comentarios