MicroMet Manual Pg. 16
Setting up a New Data Station in PC208W
PC208W is Campbell Scientific’s CR10X maintenance program that runs under
Windows. Before you can send a dld program to your CR10X or check on your physical
sensor readings, you must set up a connection between PC208W and the CR10X at the
site. These are the steps to follow:
! Start PC208W
! On the PC208W floating tool bar, press the SETUP button. This will bring up the
Setup Connections window.
! On the Setup Connections window press the Add Device button. This will bring up
a window named Add New Device.
! On the Add New Device window, select CR10X datalogger then select the Com
port with which you will communicate with the CR10X. You will want to use the Com
port on your PC which has the nine pin connector. Once the CR10X and Com port
are selected, press OK.
! On the Setup Connections window, highlite and rename the datalogger name to a
name that will make sense for this site. For example Kenai_MP for Kenai Moose
pens.
! On the Setup Connections window, set the Baud Rate to 9600.
! On the Setup Connections window press Save Edits to save the new site
connection.
! Exit Setup Connections. Your new site connection is complete.
Setting your PC’s time in Windows
PC208W uses your PC’s date and time to set the data and time in the CR10X. Before
allowing PC208W to set the CR10X date and time, you must be certain that the date
and time in your PC are correctly set to Alaska Standard Time, not Alaska Daylight
Time. Follow these steps to set your PC’s date and time:
! Right click the Time on the right side of the Windows Task Bar.
! Select Adjust Date/Time from the menu that pops up.
! All Date and Time parameters may be individually highlighted and set with the
Date/Time Properties window.
! On the Date/Time Properties window press OK to apply the new date and time to
your PC.