MicroMet Manual Pg. 9
T – Test transmission. MicroMet will turn on its transmitter and attempt to send
whatever is in its immediate transmit queue. This is a quick way to test the antenna
system. Any faults will result in warning messages. If no warnings are displayed, then
the antenna and transmitter systems are OK.
Warning: Test transmission is meaningless until a data message has been
enqueued. After a COLDSTART, set the time and use canmsg to enqueue a data
message before using Test transmission.
Version 1.05 and above will generate a single canned message if no message has been
enqueued.
Time [YY MM DD HHMM] – Display or set the unit’s real time clock.
Verbose [+] or [-] or [nn] – Display or set the level of advisories issued by MicroMet.
Any value between 1 and 100 may be entered. + increments the value by one, -
decrements the value by one. The default value is 1. A value of 5 or above will allow
MicroMet to display data reports as they are received from the CR10X (see Warnings
and Advisories, pg 10.)
Txrate [n] Display or set the sync rate at which MicroMet is allowed to respond to
AMBCS. MicroMet will respond to no more than every nth sync. This keeps remotes in
close proximity to each other from responding simultaneously. Default is 10.
Warning: Please check with the AMBCS system administrator before adjusting this
parameter!