SECTION 3. INSTRUCTION SET BASICS
3-8
TABLE 3.9-3. CR23X Output Instructions R = No. of Reps.
FINAL
INTER. MEMORY FLAG O FLAG 0
INSTRUCTION LOC.
VALUES BYTES OPTION LOW HIGH
69 WIND VECTOR 2+9R 2R 12 00, 2.7+8.3R 3.9+38.7R
3R 01, 2.7+8.3R 4.5+15.6R
4R 02, 2.4+8.8R 3.8+34.7R
2R 10, 2.1+8.2R 0.0+27.3R
3R 11, 2.1+8.2R 3.7+15.8R
4R 12, 1.6+6.4R 3.1+27.4R
70 SAMPLE 0 R 6 0.1 0.5+0.2R
71 AVERAGE 1+R R 7 0.6+0.3R 1.4+1.7R
72 TOTALIZE R R 7 0.4+0.3R 0.9+0.6R
73 MAXIMUM 1R R 8 0, 0.6+0.5R 1.6+1.4R
2R 2R, 3R 01,10,11 0.6+0.5R 1.6+2.8R
74 MINIMUM 1R R 8 0, 0.6+0.5R 1.6+1.4R
2R 2R, 3R 01,10,11 0.6+0.5R 1.6+2.8R
75 HISTOGRAM 1+bins∗R BINS*R 24 0.7+1.7R 0.8+(2.8+0.7*BIN)R
77 REAL TIME 0 1 TO 4 4 0.1 2.2
78 RESOLUTION 0 0 3 0.4 0.4
79 SMPL ON MM R R 7 0.2 0.7+0.3R
80 STORE AREA
1
007 0.2 0.2
81 RAINFLOW HIST see
instruction 42
82 STD. DEV. 1+3R R 7 0.8+1.0R 3.3+7.0R
TABLE 3.9-4. Program Control Instruction Memory and Execution Times
MEMORY
INTER. PROG.
INSTRUCTION LOC. BYTES EXECUTION TIME (ms)
83 IF CASE <F 0 10 0.23
85 LABEL SUBR. 0 3 0.08
86 DO 0 6 0.17
87 LOOP 1 10 0.16
88 IF X<=>Y 0 11 0.42
89 IF X<=>F 0 13 0.32
90 LOOP INDEX 0 3 0.40
91 IF FLAG/PORT 0 7 0.22
92 IF TIME 1 12 0.21
93 BEGIN CASE 1 8 0.16
94 ELSE 0 4 0.16
95 END 0 4 0.22
96 SERIAL OUT 0 3
97 INIT.TELE. 7 17
98 SEND CHAR. 0 3
120 GOES SAT 0 or 2 5
121 ARGOS SAT 0 8