SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES
7-16
CR23X
FIGURE 7.15-3. Hook up to AVW1
PROGRAM
AVW1 & CR23X USED TO MEASURE 1
GEOKON VIBRATING WIRE SENSOR.
* Table 1 Program
01: 60 Execution Interval (seconds)
01: Excite-Delay (SE) (P4)
1: 1 Reps
2: 15 ±5000 mV Fast Range
3: 1 SE Channel
4: 1 Excite all reps w/Exchan 1
5: 1 Delay (units 0.01 sec)
6:2500 mV Excitation
7: 1 Loc [ Temp ]
8: .001 Mult
9: 0 Offset
02: Polynomial (P55)
1: 1 Reps
2: 1 X Loc [ Temp ]
3: 1 F(X) Loc [ Temp ]
4: -104.78 C0
5: 378.11 C1
6: -611.59 C2
7: 544.27 C3
8: -240.91 C4
9: 43.089 C5
03: Vibrating Wire (SE) (P28)
1: 1 Reps
2: 2 SE Channel
3: 1 Excite all reps w/Exchan 1
4: 24 Starting Freq. (units = 100 Hz)
5: 32 End Freq. (units = 100 Hz)
6: 500 No. of Cycles
7: 0 Rep Delay (units = 0.01 sec)
8: 2 Loc [ Pressure ]
9: -34.836 Mult
10: 0 Offset