Section 11. Programming Resource Library
Scalar mean horizontal wind speed, S:
where in the case of orthogonal sensors:
Unit vector mean wind direction,
where
or, in the case of orthogonal sensors
where
Standard deviation of wind direction (Yamartino algorithm)
where,
and Ux and Uy are as defined above.