Campbell TX312 Especificaciones Pagina 56

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 96
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 55
Appendix D. RAWS-7 Data Format
D-8
; if no fuel temp sensor,
; load 999 for data value
26: If (X<=>F) (P89)
1: 7 X Loc [ FuelT ]
2: 4 <
3: -35 F
4: 30 Then Do
27: Z=F (P30)
1: 999 F
2: 0 Exponent of 10
3: 7 Z Loc [ FuelT ]
28: End (P95)
29: If (X<=>F) (P89)
1: 7 X Loc [ FuelT ]
2: 3 >=
3: 55 F
4: 30 Then Do
30: Z=F (P30)
1: 999 F
2: 00 Exponent of 10
3: 7 Z Loc [ FuelT ]
31: End (P95)
; Calculate program signature once a day
32: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 1440 Interval (same units as above)
3: 30 Then Do
33: Signature (P19)
1: 2 Loc [ Prog_Sig ]
34: End (P95)
; Calculate and hold 10 minute averages for Wspd and Wdir
; Values are written to input locations 10 and 11 (Avg10WS, Avg10WD)
35: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 10 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
; Direct output processing to input locations
36: Set Active Storage Area (P80)
1: 3 Input Storage Area
2: 10 Loc [ Avg10WS ]
Vista de pagina 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 95 96

Comentarios a estos manuales

Sin comentarios