Appendix D. RAWS-7 Data Format
D-5
; Measure Fuel Moisture
; Wiring:
; Power enable: C8
; Signal: SE 12
4: Period Average (SE) (P27)
1: 1 Reps
2: 4 200 kHz Max Freq @ 2 V Peak to Peak, Period Output
3: 12 SE Channel
4: 10 No. of Cycles
5: 5 Timeout (units = 0.01 seconds)
6: 28 Loc [ FuelM ]
7: .001 Mult
8: 0 Offset
5: Do (P86)
1: 58 Set Port 8 Low
; Measure temperature and RH (HMP45C-L)
6: Excitation with Delay (P22)
1: 1 Ex Channel
2: 0 Delay W/Ex (units = 0.01 sec)
3: 15 Delay After Ex (units = 0.01 sec)
4: 0 mV Excitation
7: Volt (SE) (P1)
1: 1 Reps
2: 25 2500 mV 60 Hz Rejection Range
3: 2 SE Channel
4: 3 Loc [ AirTemp ]
5: .1 Mult
6: -40 Offset
8: Volt (SE) (P1)
1: 1 Reps
2: 25 2500 mV 60 Hz Rejection Range
3: 1 SE Channel
4: 4 Loc [ RH ]
5: .1 Mult
6: 0 Offset
; Measure wind speed (03001-L)
9: Pulse (P3)
1: 1 Reps
2: 1 Pulse Channel 1
3: 21 Low Level AC, Output Hz
4: 5 Loc [ Wspd ]
5: 1.677 Mult ; MPH
6: 0.4 Offset
Comentarios a estos manuales