Campbell RF400 Manual Pagina 1

Busca en linea o descarga Manual para Redes Campbell RF400. Campbell RF400 Product manual [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 126
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
RF401-series and RF430-series
Spread Spectrum Data
Radios/Modems
Revision: 2/12
Copyright © 2001-2012
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 125 126

Indice de contenidos

Pagina 1 - Radios/Modems

RF401-series and RF430-seriesSpread Spectrum Data Radios/ModemsRevision: 2/12Copyright © 2001-2012Campbell Scientific, Inc.

Pagina 2

RF401/RF430 Table of Contents 10. Item #14221 900 MHz Omnidirectional Collinear, 3 dBd w/Mounts .. 18 11. Item #15970 900 MHz Indoor Dipole, 1 dBd

Pagina 3 - Warranty

Appendix I. Phone to RF401 Series 4. COM220 Dip Switches Dip Switch Position 1 Open 2 Open 3 Open 4 Open 5 Open 6 Open 7 Open 8 O

Pagina 4 - Assistance

Appendix J. Monitor CSAT3 via RF401 Series Procedure for installing a pair of RF401 series spread spectrum radios for monitoring a CSAT3 system at a

Pagina 5 - – CAUTION –

Appendix J. Monitor CSAT3 via RF401 Series J-2 (g) RS-232 Baud Rate – use the default (9600) for RF401 radios with OS3 or earlier. For RF401 radios

Pagina 6 - This is a blank page

Appendix K. RF401/RF411 Pass/Fail Tests This appendix describes a method to functionally test RF401/RF411 system components including: • PC COM port

Pagina 7

Appendix K. RF401/RF411 Pass/Fail Tests (d) Emulation: TTY (e) ASCII (f) COM1 (or any available COM port) NOTE With some versions of HyperTe

Pagina 8

Appendix K. RF401/RF411 Pass/Fail Tests TESTING RF401/RF411s After verifying the functionality of the terminal program and the integrity of the seria

Pagina 9

Appendix K. RF401/RF411 Pass/Fail Tests (9) Make sure that no antennas are attached to the RF401/RF411s (10) Label the other RF401/RF411, “Remote”

Pagina 10

Appendix K. RF401/RF411 Pass/Fail Tests (b) Choose an open area free of large2 metal objects within 10 feet of the RF401/RF411s (can be indoors or o

Pagina 11 - List of Tables

Appendix K. RF401/RF411 Pass/Fail Tests FIGURE K-3. 3 dBd 900 MHz Collinear Omni Antenna (d) Set up remote RF401/RF411 with NO antenna and with an

Pagina 12

Appendix L. RF401/RF411 Average Current Drain Calculations For remote sites with tight power budgets due to solar or battery power supplies, the foll

Pagina 13 - Spectrum Radio/Modems

RF401/RF430Table of Contents List of Tables 1. PC Driver Installation ...

Pagina 14 - 1.2 RF430-series Radios

Appendix L. RF401/RF411 Average Current Drain Calculations The base RF401/RF411’s total average current (It) can be calculated over an interval (T) a

Pagina 15

Appendix L. RF401/RF411 Average Current Drain Calculations EXAMPLE #1 (Remote RF401/RF411 in default standby mode) There is a Point-to-Point system

Pagina 16 - 2. Specifications

Appendix L. RF401/RF411 Average Current Drain Calculations EXAMPLE #2 (Base RF401/RF411 in default standby mode) The base RF401/RF411 in the above

Pagina 17

Appendix L. RF401/RF411 Average Current Drain Calculations EXAMPLE #3 (Base RF401/RF411 in “<0.4 mA, 8 sec Delay” standby mode) The RF401/RF411s

Pagina 18 - 3. Installation

Appendix L. RF401/RF411 Average Current Drain Calculations EXAMPLE #4 (Remote RF401/RF411 in “<0.4 mA, 8 sec Delay” standby mode) The RF401/RF41

Pagina 19

Appendix L. RF401/RF411 Average Current Drain Calculations EXAMPLE #5 (Base RF401/RF411 in default “<4 mA, 1 sec Delay” standby mode) The RF401/

Pagina 20

Appendix L. RF401/RF411 Average Current Drain Calculations EXAMPLE #6 (Base RF401/RF411 in “<0.4 mA, 8 sec Delay” standby mode) The RF401/RF411s

Pagina 21 - LoggerNet

Appendix L. RF401/RF411 Average Current Drain Calculations EXAMPLE #7 (Remote RF401/RF411 in “<0.4 mA, 4 sec Cycle” standby mode ) The RF401/RF

Pagina 22

Appendix L. RF401/RF411 Average Current Drain Calculations L-10

Pagina 23 - 3.2.4 Step 4 – Connect

Appendix M. PakBus Networking Details M.1 PakBus Aware, PakBus Node, and RF PakBus Both the PakBus Aware and PakBus Node settings use the RF PakBus

Pagina 24 - 4. System Components

RF401/RF430 Table of Contents vi

Pagina 25 - 4.2 Power Supplies

Appendix M. PakBus Networking Details M.3 Maximizing the RF Packet Size The radio module’s RF packet size is changed from the default 64 bytes to i

Pagina 26

Appendix M. PakBus Networking Details The RF401 or RF430 will not reduce the hop metric, only increase it. The radio compares the hop metric of the

Pagina 27 - 4.3 Serial and USB Cables

Appendix M. PakBus Networking Details Beacon Interval: 60 seconds Verify Interval: 150 seconds Hello List: None Central Router: None M.8 Optimiz

Pagina 28 - 4.4 Compatible Antennas

Appendix M. PakBus Networking Details from PakBus node 4088 and 4089. That is, the radio temporarily “assumes” the PakBus identity of 4088 or 4089 un

Pagina 29

Appendix M. PakBus Networking Details M-6

Pagina 31

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 32

RF401-series and RF430-series Spread Spectrum Radio/Modems 1. Introduction This manual discusses the RF401-series and RF430-series spread spectrum ra

Pagina 33 - 4.5.2 Electro-static Issues

RF401-series and RF430-series Spread Spectrum Radio/Modems • RF401 915 MHz Spread Spectrum Radio—transmits data to another RF401 radio, an RF430 radi

Pagina 34 - 5. Software

RF401-series and RF430-series Spread Spectrum Radio/Modems • RF431 922 MHz Spread Spectrum Radio—transmits data to another RF431 radio, an RF411 radi

Pagina 35

RF401-series and RF430-series Spread Spectrum Radio/Modems • Ethernet network to radio: PC to Internet to NL100 to radio to datalogger (use LoggerNe

Pagina 36

RF401-series and RF430-series Spread Spectrum Radio/Modems Quiescent Current in Standby Modes* Avg. Quiescent Current (mA) Advanced Setup Standby Mo

Pagina 37

RF401-series and RF430-series Spread Spectrum Radio/Modems 3. Installation 3.1 Site Considerations Location of a radio near commercial transmitters,

Pagina 38

RF401-series and RF430-series Spread Spectrum Radio/Modems c. If using an RF430, install the USB drivers to the PC by doing the following procedures.

Pagina 40 - 5.1.3 PakBus Tab

RF401-series and RF430-series Spread Spectrum Radio/Modems d. If using an RF401, plug AC adapter into AC outlet and plug barrel connector into the ba

Pagina 41 - 5.2 LoggerNet

RF401-series and RF430-series Spread Spectrum Radio/Modems - RX LED Test - To determine if there is a neighboring radio network in operation using the

Pagina 42

RF401-series and RF430-series Spread Spectrum Radio/Modems TABLE 2. Lacking 12 V on CS I/O Pin 8 EQUIPMENT SERIAL NUMBER CR500 < 1765 CR7 700X Bd

Pagina 43

RF401-series and RF430-series Spread Spectrum Radio/Modems b. For the datalogger settings, set the Baud Rate to match the radio’s RS-232 baud rate.

Pagina 44

RF401-series and RF430-series Spread Spectrum Radio/Modems 3.3 Antenna Considerations 3.3.1 Line of Sight The single most important factor in radio

Pagina 45

RF401-series and RF430-series Spread Spectrum Radio/Modems the red LED will light steadily. When the RF401 is transmitting, the red LED will pulse OF

Pagina 46 - 5.2.2 Network Planner

RF401-series and RF430-series Spread Spectrum Radio/Modems TABLE 3. 15966’s Voltage Regulation Current Drain (mA) Resistive Load (Ohms) AC Adapter O

Pagina 47 - 5.2.3 PakBus Graph

RF401-series and RF430-series Spread Spectrum Radio/Modems 4.2.2 Remote Sites with Datalogger At the remote site, an RF401 radio is usually powered b

Pagina 48 - 6. Troubleshooting

RF401-series and RF430-series Spread Spectrum Radio/Modems 4.4 Compatible Antennas The 900 MHz antennas are compatible with the RF401, RF411, RF430,

Pagina 49

RF401-series and RF430-series Spread Spectrum Radio/Modems 16755 2.4 GHz, 13 dBd ANTENNA, ENCLOSED YAGI, allows vertical or horizontal polarization,

Pagina 50

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Pagina 51 - Warning

RF401-series and RF430-series Spread Spectrum Radio/Modems FIGURE 8. Item #14201 900 MHz Yagi, 9 dBd w/Mounts FIGURE 9. Item #14205 900 MHz Yagi

Pagina 52

RF401-series and RF430-series Spread Spectrum Radio/Modems FIGURE 11. Item #15970 900 MHz Indoor Dipole, 1 dBd Window/Wall Mounted FIGURE 12. It

Pagina 53

RF401-series and RF430-series Spread Spectrum Radio/Modems FIGURE 13. Item #16755 2.4 GHz Enclosed Yagi, 13 dBd w/Mounts FIGURE 14. Example COAX

Pagina 54

RF401-series and RF430-series Spread Spectrum Radio/Modems 4.5 Antenna Cables and Surge Protection 4.5.1 Antenna Cables The 14201, 14203, 14205, 142

Pagina 55 - B.2.4 Sync Timer Setting

RF401-series and RF430-series Spread Spectrum Radio/Modems FIGURE 16. Enclosure with Antenna Surge Protector for RF401 5. Software 5.1 DevConfig R

Pagina 56

RF401-series and RF430-series Spread Spectrum Radio/Modems (4) Click on “RF401” or “RF430” for the device type in DevConfig. (5) Select the port mat

Pagina 57

RF401-series and RF430-series Spread Spectrum Radio/Modems 5.1.2.1 Active Interface The only Active Interface settings that are available for the RF4

Pagina 58

RF401-series and RF430-series Spread Spectrum Radio/Modems by using RF level packet acknowledgements and retries. This is done for any size network. D

Pagina 59

RF401-series and RF430-series Spread Spectrum Radio/Modems If the RF430’s operating system is prior to OS2, its USB port will only communicate at 38.4

Pagina 60

RF401-series and RF430-series Spread Spectrum Radio/Modems 5.1.2.9 Power Modes The radio’s average idle current can be set with the following Standby

Pagina 61

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 62

RF401-series and RF430-series Spread Spectrum Radio/Modems 5.1.3 PakBus Tab FIGURE 18. PakBus tab in DevConfig (with Default Settings) The settings

Pagina 63 - CR206(X) Communications

RF401-series and RF430-series Spread Spectrum Radio/Modems Defaults can often be used for the other settings provided in the PakBus tab. The default

Pagina 64

RF401-series and RF430-series Spread Spectrum Radio/Modems FIGURE 19. Select RF4XX for connection type for a multipoint (non PakBus) network. FIGUR

Pagina 65

RF401-series and RF430-series Spread Spectrum Radio/Modems 5.2.1.1 Standard Setup (RF400) FIGURE 21. Default Screen for the RF400 Standard Setup in

Pagina 66

RF401-series and RF430-series Spread Spectrum Radio/Modems is about to be exceeded. The dialog box has Reset Max Time and Don’t Reset buttons. If the

Pagina 67

RF401-series and RF430-series Spread Spectrum Radio/Modems 5.2.1.2 Standard Setup (RF400 Remote) FIGURE 22. Default Screen for the RF400 Remote Sta

Pagina 68

RF401-series and RF430-series Spread Spectrum Radio/Modems buttons. If the Reset Max Time button is pressed, the Max Time On-Line counter will be rese

Pagina 69

RF401-series and RF430-series Spread Spectrum Radio/Modems 5.2.3 PakBus Graph PakBus Graph is a LoggerNet utility that graphically depicts the device

Pagina 70

RF401-series and RF430-series Spread Spectrum Radio/Modems 6. Troubleshooting If you can’t connect, check out these possible causes: 1. Datalogger o

Pagina 71

RF401-series and RF430-series Spread Spectrum Radio/Modems 7. Radio receiver is “de-sensing” from nearby transmitter. This problem can be observed f

Pagina 72

– CAUTION – Where an AC adapter is used, CSI recommends Item # 15966. Any other AC adapter used must have a DC output not exceeding 16.5 Volt

Pagina 73

RF401-series and RF430-series Spread Spectrum Radio/Modems 38 c. Change polarization (element orientation) of all yagi and collinear antennas in your

Pagina 74

Appendix A. Part 15 FCC Compliance Warning Changes or modifications to the RF401 series radio systems not expressly approved by Campbell Scientific,

Pagina 75 - Configurations

Appendix A. Part 15 FCC Compliance Warning A-2

Pagina 76

Appendix B. Advanced Setup Menu B.1 Accessing the Advanced Menu The standard Setup Menu is described in Section 5.1. The advanced Setup Menu can be

Pagina 77

Appendix B. Advanced Setup Menu (4) AT Command Mode Timeout (units of 100 msec; 1 – 32767) iv) Radio Diagnostics Number of Retry Failures: R

Pagina 78 - F.4 PC208W Configuration

Appendix B. Advanced Setup Menu B.2 Error Handling and Retries In the RF module received packets are analyzed for data corruption with an embedded C

Pagina 79

Appendix B. Advanced Setup Menu send the same packet up to 3 times; each time looking for an ACK packet back from the receiving radio. If it does no

Pagina 80

Appendix B. Advanced Setup Menu TABLE B-1. Advanced Setup Menu STANDBY MODE STANDBY AVG RECEIVE CURRENT Wake-up Interval (red LED flash interval)

Pagina 81 - CR10X WIRING PANEL

Appendix B. Advanced Setup Menu B-6 LONG HEADER TIME Sets long header duration in tenths of a second. The default is 7 (for 0.7 seconds). If change

Pagina 82

Appendix C. Address and Address Mask Address The address is 16 bits: (0 - 1111,1111,1111,1111) binary (0 - ffffh) hexadecimal 0 – 65535) decim

Pagina 83

This is a blank page.

Pagina 84 - How Far Can You Go?

Appendix C. Address and Address Mask four bits are not compared, any remote radio with Radio Address of 0 to 1111 (decimal 0 to 15) will be received

Pagina 85 - Cable Loss

Appendix C. Address and Address Mask NET ADDRESS(decimal) RADIO ADDRESS(decimal) COMBINED 16-BIT ADDRESS(hexadecimal) 0 29 001D 0 30 001E 0 31 001

Pagina 86 - Path Loss

Appendix C. Address and Address Mask C-4 NET ADDRESS(decimal) RADIO ADDRESS(decimal) COMBINED 16-BIT ADDRESS(hexadecimal) 15 0 3C00 15 1 3C01 1

Pagina 87

Appendix D. Setting Up RF401-to-CR206(X) Communications Certain CR206(X) settings must match the RF401 settings for communications between the datalo

Pagina 88 - Examples

Appendix D. Setting Up RF401-to-CR206(X) Communications 5. Network: must match the Network Address setting for all RF401 or RF430 radios in the Net

Pagina 89

Appendix D. Setting Up RF401-to-CR206(X) Communications FIGURE D-2. This graph represents a transmitting radio that uses a long header and a receiv

Pagina 90

Appendix D. Setting Up RF401-to-CR206(X) Communications Below is a description of all of the Power Mode options: • No Radio—datalogger model has no

Pagina 91 - I.1 PakBus Network

Appendix D. Setting Up RF401-to-CR206(X) Communications FIGURE D-4. DevConfig Deployment panel showing the CR206(X) setup for Example 1. D-5

Pagina 92 - (null-modem)

Appendix D. Setting Up RF401-to-CR206(X) Communications RF401 Setup for Example 1 (see Figure 5): 1. Since the RF401 will connect to a PC, select Au

Pagina 93

Appendix D. Setting Up RF401-to-CR206(X) Communications D.3 Example Setup 2 - Router to CR206(X) The following is a typical setup of an RF401 cabled

Pagina 94

RF401/RF430 Series Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab

Pagina 95

Appendix D. Setting Up RF401-to-CR206(X) Communications RF401 #1 Setup for Example 2 (see Figure D-7) 1. Since RF401 #1 will connect to a PC, select

Pagina 96

Appendix D. Setting Up RF401-to-CR206(X) Communications RF401 #2 Setup for Example 2 (see Figure D-8) 1. For RF401 #2 , select Datalogger SDC 7 (or

Pagina 97 - I.2 Non-PakBus Network

Appendix D. Setting Up RF401-to-CR206(X) Communications D-10

Pagina 98 - ------------ RF401-DL2

Appendix E. Port Pin Descriptions RS-232 Port The “RS232” port is a partial implementation of RS-232C. It is configured as Data Communications Equip

Pagina 99

Appendix E. Port Pin Descriptions E-2 CS I/O CONNECTOR, 9-PIN D-SUB MALE PIN FUNCTION I/O DESCRIPTION 1 5V I Sources 5 VDC to power peripheral

Pagina 100

Appendix F. Non-PakBus Example Configurations The following procedures explain how to build a basic RF401 point-to-point network and a point-to-multi

Pagina 101

Appendix F. Non-PakBus Example Configurations - RX LED Test - To determine if there is a neighboring RF401 network in operation using the same hoppin

Pagina 102

Appendix F. Non-PakBus Example Configurations F.3 LoggerNet Configuration (Transparent Protocol) There are two ways of configuring the Setup map for

Pagina 103

Appendix F. Non-PakBus Example Configurations (3) Extra Response Times are typically 0 s RF400 RF400RF400RF400DATALOGGER DATALOGGERDATALOGGER CS I/

Pagina 104

Appendix F. Non-PakBus Example Configurations (3) Generic Modem Settings (a) √ “Make DTR Active” (b) √ “Hardware Flow Control” (c) Extra R

Pagina 105 - TESTING RF401/RF411s

RF401/RF430 Table of Contents 5.1.2 RF401/RF411/RF416 or RF430/RF431/RF432 Tab... 23 5.1.2.1 Active Interface ...

Pagina 106 - TESTING ANTENNAS

Appendix F. Non-PakBus Example Configurations FIGURE F-2. PC208W Datalogger Generic Dial String F-6

Pagina 107

Appendix G. Short-Haul Modems Set SRM-5A at PC end to “DCE” mode. Set SRM-5A at RF401 end to “DTE” mode. The PC to SRM-5A cable is typically a 9-pin

Pagina 108 - RatioPower ft. 5 ×

Appendix G. Short-Haul Modems With short-haul modems it is necessary to configure the base station RF401’s “RS-232 Auto Power Down Enable” (in the Ad

Pagina 109 - Current Drain Calculations

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors You may test the radio communications by using the 21107 900 MHz Spread Spectrum De

Pagina 110

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors theoretically extends the attainable distance by a factor of 2.8. Adding 9 dBd yag

Pagina 111

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors Where: Pt => transmitter output power, in dBm (20 dBm in the case of the RF401

Pagina 112

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors CSI’s “COAX RPSMA-L” uses LMR-195 antenna cable. Cable loss is proportional to len

Pagina 113

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors Here is a table showing the free space path loss (in dB). Note the effect of frequ

Pagina 114

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors Rain, Snow, and Fog Below 10 GHz, these don’t have much effect on path loss (see Gr

Pagina 115

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors Here’s the equation we will use, from the first page: Pt - Lt + Gt - Lp + Gr - Lr =

Pagina 116

RF401/RF430Table of Contents F. Non-PakBus Example Configurations ... F-1 F.1 Direct PC to RF401 Series Base Station Setup (Transpar

Pagina 117

Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors H-8

Pagina 118

Appendix I. Phone to RF401 Series I.1 PakBus Network Use of the Network Planner may be the easiest method of configuring a phone-to-RF401 PakBus net

Pagina 119 - Details

Appendix I. Phone to RF401 Series 1. HARDWARE REQUIREMENTS a. RF401s with OS4 or greater b. COM220 c. A100/PS100 or CH100 d. AC charger (CSI Item

Pagina 120

Appendix I. Phone to RF401 Series If there is a neighboring RF401 network, you should change the Hopping Sequence of base and remote RF401s to a new

Pagina 121 - M.7 RF Router

Appendix I. Phone to RF401 Series FIGURE I-2. Phone base configuration. I-4

Pagina 122 - M.9 Idiosyncrasies

Appendix I. Phone to RF401 Series FIGURE I-3. Enter the base site’s phone number. I-5

Pagina 123

Appendix I. Phone to RF401 Series FIGURE I-4. Enter 250 for the Maximum Packet Size. 4. HARDWARE After configuring LoggerNet and the RF401s you

Pagina 124

Appendix I. Phone to RF401 Series I.2 Non-PakBus Network Where a phone to RF401 Base is desired in a non-PakBus network, the following configuration

Pagina 125

Appendix I. Phone to RF401 Series If there is a neighboring RF401 network, you should change the Hopping Sequence of base and remote RF401s to a new

Pagina 126

Appendix I. Phone to RF401 Series b. Remote RF401s 1) Radio Addresses: 1, 2, etc. (unique for each remote RF401 and must agree with respective RF401

Comentarios a estos manuales

Sin comentarios