CS451/CS456 Submersible Pressure Transducer
6. Specifications
Features:
• Output acceptable for recording devices with SDI-12 or RS-232
capability including Campbell Scientific dataloggers
• Quality construction that ensures product reliability
• Rugged stainless steel or titanium case that protects piezoresistive
sensor
• Fully temperature compensated
• Low power sleep state between measurements that reduces power
consumption
• Weighted nose cone offered that adds 0.2 kg (7.4 oz) to the
transducer’s weight. Additional weight makes submersion of the
transducer easier
Compatible Dataloggers: CR200(X) series
CR800
CR850
CR1000
CR3000
CR5000
CR500
CR510
CR10(X)
CR23X
Power Requirements: 5 to 18 Vdc
Power Consumption: Quiescent current < 50 µA
Measurement/Communication Current: 8
mA for 1-s measurement
Maximum Peak Current: 40 mA
Measurement Time: Less than 1.5 s
Outputs: SDI-12 (version 1.3) 1200 bps
RS-232 9600 bps
Measurement Ranges:
Pressure (psig) Pressure (kPa) Depth of fresh water
0 to 2.9 0 to 20 0 to 2 m (6.7 ft)
0 to 7.25 0 to 50 0 to 5.1 m (16.7 ft)
0 to 14.5 0 to 100 0 to 10.2 m (33.4 ft)
0 to 29 0 to 200 0 to 20.4 m (67 ft)
0 to 72.5 0 to 500 0 to 50.9 m (167 ft)
0 to 145 0 to 1000 0 to 102 m (334.5 ft)
Accuracy: ±0.1% full scale range TEB* or
±0.05% full scale range TEB**
Resolution: 0.0035% full scale range
8
Comentarios a estos manuales