Raven XT-Rogers Sierra Wireless Cellular Modem
Connect to the modem with AceManager (Section 5.3). Select the “Serial”
Group, and make sure the “AT Verbose Mode” is set to “Numeric” for use
with the CR10(X), CR510, and CR23X dataloggers, or “Verbose” for other
dataloggers (e.g. CR1000).
The “Raven XT Template 9600” template file sets the baud rate to 9600, which
is the maximum baud rate for the CR10X and older dataloggers. For newer
dataloggers, the baud rate can be changed to the highest baud rate supported by
the datalogger (e.g. 115200 baud for the CR1000).
Baud rate changes require the modem to be reset before the
change takes affect. Click the Reset icon in AceManager to the
reset the modem and implement the change.
NOTE
18