Appendix B. Status Table
B-6
Status Fieldname Description Variable
Type
Default Normal
Range
User can
change?
Info
Type
CommActive
15
Array of Boolean values telling if
communications is currently active on
the corresponding port. Aliased to
CommActiveRS-232,
CommActiveME,
CommActiveCOM310,
CommActiveSDC7,
CommActiveSDC8,
CommActiveSDC10
CommActiveSDC11
CommActiveCOM1,
CommActiveCOM2,
CommActiveCOM3,
CommActiveCOM4
Boolean
array of
9
False,
except
for the
active
COM
True or
False
_ Status
CommConfig Array of values telling the
configuration of comm ports. Aliased to
CommConfigRS-232,
CommConfigME,
CommConfigCOM310,
CommConfigSDC7,
CommConfigSDC8,
CommConfigSDC10
CommConfigSDC11
CommConfigCOM1,
CommConfigCOM2,
CommConfigCOM3,
CommConfigCOM4
Integer
array of
9
RS-
232-
SDC8
= 4
COM1-
4 = 0
0 or 4 _ Config
Baudrate
16
Array of baudrates for comms. Aliased
to: BaudrateRS-232,
BaudrateME,
BaudrateSDC
BaudrateCOM1
BaudrateCOM2
BaudrateCOM3
BaudrateCOM4
Integer
array of
9
RS-
232=-
115200
ME-
SDC8 =
115200
COM1-
4 = 0
1200,
2400,
4800,
9600,
19.2k,
38.4k,
57.6k,
115.2k
Yes, can
also use
SerialOut
instructio
n to setup.
Config
IsRouter Is the CR1000 configured to act as
router
Boolean False 0 or 1 Yes Config
PB
PakBusNodes Number of nodes (approximately) that
will exist in the PakBus network. This
value is used to determine how much
memory to allocate for networking.
Integer 50 >=50 Yes Config
PB
CentralRouters(1) - (8)
17
Array of (8) PakBus addresses for
central routers.
Integer
array of
8
0 _ Yes Config
PB