3. In order to setup access to the datalogger via LoggerNet and the
PakBus/TCP Service Port, the following rule configuration needs to be added
and applied:
x Enter a Rule Name
x Internal Server IP = 192.168.0.99 (this is the IP address assigned to
the datalogger)
x Internal Port = 6785
x Protocol = TCP
x External Port = 6785
x Click ‘Add’, then ‘Apply’
Be sure to include the external port number in any communications attempting
to reach the datalogger (ex.:173.182.77.117:6785).
NOTE