Call-Back Configuration for the CR800/CR1000 – MultiLogger Application Note #19 – Page 11 of 12
MultiLogger Enable Call-Back and Agent Configuration
Before activating the Agent be sure Call-Back is enabled for the ports that have dataloggers attached that
you wish to receive call-back events from.
For RS-232 Direct Call-Back select the COM port to be used to receive the call-back events. Check Allow
Call-back and then configure the Highest Call-back Baud Rate to match the setting in the programming
used for the Alarm Action.
When using any of the Modem Call-back Alarm Actions select the Modem node and check Allow Call-
back. The baud rate is negotiated between the modems so there is no baud rate setting.
Note: Only one device per Gateway can have call-back enabled. If the same computer must use
COM and Modem call-backs then configure a second local Gateway. Separate the 2 ports to each
Gateway, for example the COM device could be on Gateway1, the Modem on Gateway2.