9522B Iridium Satellite Modem
_____________________________________________________________________________
18
3.1.5. Step 5: Generic Hardware Configuration
In the Generic element be sure that the Communications
Enabled box is checked, change the Maximum Baud Rate to
19200 (9600 for a CR10X), add 2 seconds to the Extra
Response Time, and add 200 ms to the Delay Hangup (Figure
18). The remaining settings can be left in their default state.
Once complete move to Step 6 to finish the configuration of the
Generic element.
Figure 18: Generic - Hardware Configuration
3.1.6. Step 6: Generic Modem Configuration Continued
Click on the Modem tab located next to the Hardware tab (Figure
19). In the Dial Script box enter D8000. This will program the
software to expect an 8 second delay in communications, which
is common in many satellite applications. The remaining settings
can be left in their default state.
If you are communicating with a PakBus datalogger, follow the
configuration listed in Step 7. Otherwise ignore Step 7 and move
to Step 8.