Design Features
Modular system that consists of a base system
and a chassis with I/O module slots. Up to nine
user-selected modules insert in the CR9000X or
ve user-selected modules in the CR9000XC
Measurement rate of up to 100 K samples/second
16-bit resolution with programmable gain
Powerful instruction set that supports measure-
ment of most sensor types, on-board processing,
data reduction, and intelligent control
128 Mbytes of internal SDRAM for data and
program storage
Expandable memory using a PCMCIA card or a
CompactFlash
®
card through the use of an adapter
Robust ESD protection
CE compliant
Low power, 12 Vdc operation
Data values stored in tables with a time stamp
and record number
Operating temperature range of -25° to +50°C;
extended range of -40° to +70°C available
180 MHz clock speed
Base System
CR9032 CPU Module
is 32-bit CPU module provides system control, data
processing, and communications.  e CR9032 features
a clock speed of 180 MHz and 128 Mbytes of internal
SDRAM for data and program storage. It also includes
an RS-232 DCE port, 10baseT/100baseT port, CS I/O
port, and a PC-card slot.  e CS I/O port supports
communications with our SDM device at rates up to
115,200 bps.  e PC-card slot accepts one Type I,
Type II, or Type III PCMCIA card. CompactFlash
cards are supported with an adapter. Industrial grade
Compact-Flash cards o ered by Campbell Scienti c
store 256 Mbytes, 1 Gbyte, or 2 Gbytes of data.
Power Supply
e power supply consists of the sealed rechargeable
battery module, universal ac adapter, and CR9011 Power
Supply Module.  e battery module has a 14 Ah rating for
the CR9000X and a 7 Ah rating for the CR9000XC.  e
batteries are recharged using the universal ac adapter, a dc
input, or another external source.
e CR9011 module controls the current  owing to
the charging source. A relay included in the CR9011
allows the datalogger to turn the power on and o .
is conserves power and increases the battery’s life.
CR9000
AC ADAPTOR
Removable panel for
attaching custom
connectors.
Sealed, rechargeable
battery modules.
Universal ac adapter.
Slots for I/O modules:
a CR9000X provides
nine slots (shown);
the CR9000XC
provides five.
Rigid, welded
aluminum chassis.
Base system that consists of the CR9011
Power Supply Module, CR9032 CPU Module
and CR9041 A/D Module.
Wiring cover included
with enclosure.
8253 CR9000X Fiberglass
Environmental Enclosure
(lid not shown).
CR9000X & CR9000XC