GPS16X-HVS GPS Receiver
3. Wiring
The GPS16X-HVS connects directly to a CR800, CR850, CR1000, or CR3000
datalogger (see Figure 2 and Table 3-1). Refer to Appendix B.1 if connecting
the receiver to a CR23X. Our CR5000 and CR9000X connect to the receiver
via the SC110 and an SDM-SIO4 (see Appendix C).
If the GPS16X-HVS is to be connected to a computer to change the default
settings, an SC110 cable is needed (see Appendix A).
TABLE 3-1. Datalogger Wiring
GPS16X-HVS Datalogger Function
Red 12V Power In
Black Ground Power Ground
Yellow Ground Power Switch
White Control Port (RX) TXD
Gray Control Port (TX) PPS
Blue Ground in operation
Send data to receiver for
configuration
R
x
data
Shield Ground Shield
FIGURE 2. CR1000 to GPS16X-HVS Connection