- jumper from terminal SW 12V CTRL to terminal C1.
3.4.3 Use
The operation of the CS500 is fully automatic and no user action is required. The appropriate operating instructions
are included in the METSTAT datalogger program.
3.4.4 Maintenance
The CS500 only requires minimal maintenance, as follows:
• DuringeachvisittotheMetStation,checkiftheradiationshieldisfreefromdustanddebris;
• Eachtwoyears,replacethehumiditychip(contactCampbellScientific).
3.4.5 Trouble Shooting
Problem 1: Temperature and or Relative Humidity values are zero.
Remedy 1.1: Check if all CS500 wires are properly connected to the CR10X wiring panel. The reader is referred
to table 1 in paragraph 2.2, and Annex 2, for the correct wiring of the CS500 to the CR10X.
Remedy 1.2: Re-load METSTAT following the instructions given in paragraph 2.5.