Campbell Met One 034A-L Manual de instrucciones

Busca en linea o descarga Manual de instrucciones para De medición, control y control Campbell Met One 034A-L. Campbell Met One 034A-L Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL Met One 034B Wind Set Revision: 9/14 Copyright © 1980- 2014 Campbell Scientific, Inc.

Pagina 2

Met One 034B Wind Set 3.1 Ships With List The 034B Wind Set ships with: (1) 1/16-inch Allen wrench (1) Bushing from Met One (1) Calibration Sheet (3

Pagina 3 - Limited Warranty

Met One 034B Wind Set determining True North using a compass and the magnetic declination for the site. 7. Remove the alignment screw at the base of

Pagina 4 - Assistance

Met One 034B Wind Set FIGURE 4-2. CM200 Series Crossarm with CM220 Right Angle Mounting Bracket 4.2 Step 2—Use Short Cut to Program Datalogger and

Pagina 5 - Precautions

Met One 034B Wind Set 3. When Short Cut opens, select New Program. 4. Select Datalogger Model and Scan Interval (default of 5 seconds is OK for mo

Pagina 6

Met One 034B Wind Set 5. Under the Available Sensors and Devices list, select the Sensors | Meteorological | Wind Speed & Direction folder. Sele

Pagina 7 - Table of Contents

Met One 034B Wind Set 8. If LoggerNet, PC400, RTDAQ, or PC200W is running on your PC, and the PC to datalogger connection is active, you can click Fi

Pagina 8 - Figures

Met One 034B Wind Set 6.1 Wind Speed Operating Range: 0 to 75 m s–1 (0 to 167 mph) Threshold: 0.4 m s–1 (0.9 mph) Accuracy: ±0.12 m s–1 (±0.25 mph

Pagina 9

Met One 034B Wind Set 7.2 Mounting Options The 034B can be attached to a CM200-series crossarm via a 17953 NU-RAIL fitting or a CM220, Right Angle Mo

Pagina 10 - 4. Quickstart

Met One 034B Wind Set The dataloggers can also measure wind speed on a control port. With this option the black wire is connected to the 5 V terminal

Pagina 11

Met One 034B Wind Set The expression for wind speed (U) is: U = MX + B where M = multiplier X = number of pulses per second (Hertz) B

Pagina 13

Met One 034B Wind Set 7.4.4 Long Lead Lengths When sensor lead length exceeds 100 feet, the settling time allowed for the measurement of the vane sho

Pagina 14

Met One 034B Wind Set Symptom: Incorrect wind direction 1. Verify that the excitation voltage, range code, multiplier and offset parameters are corre

Pagina 15 - 6. Specifications

Met One 034B Wind Set 14

Pagina 16 - 7. Installation

Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement • Ho

Pagina 17 - 7.3 Wiring

Appendix A. Importing Short Cut Code After pasting, edit the information such that a ' character (single quotation mark) begins each line. This

Pagina 18 - 7.4 Programming

Appendix B. Example Program The following CR1000 program measures the 034B every 5 seconds, and store mean wind speed, unit vector mean direction, a

Pagina 19 - 7.4.2 Wind Direction

Appendix B. Example Program B-2

Pagina 20 - 9. Troubleshooting

Appendix C. Wind Direction Sensor Orientation C.1 Determining True North and Sensor Orientation Orientation of the wind direction sensor is done af

Pagina 21 - 10. References

Appendix C. Wind Direction Sensor Orientation FIGURE C-1. Magnetic declination for the contiguous United States (2004) C-2

Pagina 22 - Met One 034B Wind Set

Appendix C. Wind Direction Sensor Orientation FIGURE C-2. Declination angles east of True North are subtracted from 0 to get True North FIGURE C-3

Pagina 23

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Pagina 24

Appendix C. Wind Direction Sensor Orientation C-4

Pagina 25 - Appendix B. Example Program

Appendix D. Wind Direction Measurement Theory It is not necessary to understand the concepts in this section for the general operation of the 034B,

Pagina 26

Appendix D. Wind Direction Measurement Theory D-2

Pagina 28

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Pagina 29

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 30

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Pagina 32

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Pagina 33

Table of Contents B. Example Program ..... B-1 C. Wind Direction Sensor Orientation ...

Pagina 34

Met One 034B Wind Set 1. Introduction The 034B Wind Set combines a 3-cup anemometer and vane into a single integrated package to measure wind speed

Comentarios a estos manuales