INSTRUCTION MANUAL
Hydrosense
Revision: 2/01
Copyright (c) 1999-2001
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 25 26

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

INSTRUCTION MANUALHydrosenseRevision: 2/01Copyright (c) 1999-2001Campbell Scientific, Inc.

Pagina 2 - Warranty and Assistance

HydroSense64.5 Measuring Volumetric Water ContentTo measure volumetric water content fully insert probe rods and press READ.The correct rod length mu

Pagina 3 - HydroSense Table of Contents

HydroSense7RWC 33 Site 1Deficit mm 34 20RelativeWaterContentSiteCurrentlySelectedDeficit12 cm ProbeDeficit20

Pagina 4

HydroSense8WC 33 Site1Deficit 34 20MENUSELECTSiteExitMENUSELECTMENUSELECTREADENTERSite1Site2..5READENTERCalExitMENUSELECTCal0Cal100MENUSELECTREADENTER

Pagina 5 - HydroSense

HydroSense9prompt is displayed. With CAL 0 displayed, the probe rods are inserted andthe READ button is pressed. This stores the measured value in H

Pagina 6 - 2. Specifications

HydroSense106.1 Probe Rod InsertionMaking a measurement with HydroSense is a simple matter of inserting theprobe rods and pressing the READ button.

Pagina 7 - 3. Unpacking and Setup

HydroSense11rocky soil, the measured water content can differ by several percent if a largerock occupies part of the sensitive volume of one measureme

Pagina 8 - 4.2 Display Information

HydroSense12making it possible to relate water content to measured dielectric permittivity.Additionally, water and air are the only soil constituents

Pagina 9

HydroSense138. Maintenance8.1 Replacing BatteryFIGURE 8-1. Rear view of the HydroSense display unit with batterycover removedThe only user-replacea

Pagina 10 - 5. Water Deficit Mode

HydroSense14The friction between the rod collar and the insert surface along with threadfriction will generally provide good rod attachment and loosen

Pagina 11

A-1Appendix A. Definition of WaterContent TermsA.1 Definition of Water Content TermsSoil water content is expressed on a gravimetric or volumetric b

Pagina 12

Warranty and AssistanceThe HYDROSENSE is warranted by CAMPBELL SCIENTIFIC, INC. to befree from defects in materials and workmanship under normal use a

Pagina 13 - Limitations

Appendix A. Definition of Water Content TermsA-2θθρρvgsoilwater=∗=−026733. cm cmερρ=− =− =−−11132605033bulksolid... g cm g cmThe porosity of

Pagina 14 - 6.1 Probe Rod Insertion

B-1Appendix B. How Many Soil WaterContent Measurements Are EnoughB.1 Introduction to Spatial VariabilitySoil water content can vary significantly am

Pagina 15

Appendix B. How Many Soil Water Content Measurements Are EnoughB-2The relationship between confidence interval and probability can be describedusing

Pagina 16

Appendix B. How Many Soil Water Content Measurements Are EnoughB-3N is the number of water content measurements and L is the acceptable rangeas defin

Pagina 17 - 8. Maintenance

Appendix B. How Many Soil Water Content Measurements Are EnoughB-4This is a blank page.

Pagina 18

This is a blank page.

Pagina 19 - Content Terms

Campbell Scientific CompaniesCampbell Scientific, Inc. (CSI)815 West 1800 NorthLogan, Utah 84321UNITED [email protected]

Pagina 20

iHydroSense Table of ContentsPDF viewers note: These page numbers refer to the printed version of this document. Usethe Adobe Acrobat® bookmarks tab

Pagina 21 - B.2 An Example

HydroSense Table of ContentsiiA. Definition of Water Content Terms ...A-1A.1 Definition of Water Content Terms...

Pagina 22

1HydroSense1. General DescriptionFIGURE 1-1. HydroSense display unit and probe with 12 cm rods.1.1 IntroductionThe HydroSense Soil Water Content Me

Pagina 23

HydroSense21.2 HydroSense ModesThe Water Content Measurement Mode displays the measurement result aspercent volumetric water content and shows the pe

Pagina 24 - This is a blank page

HydroSense3Weight approx 400 gmCable Spiral cable, 200cm extended.*saturation is typically around 50% volumetric water content3. Unpacking and Setup•

Pagina 25

HydroSense4VWC 0% P12cmPeriod 0.77msMENUSELECTIn Water Content Measurement Mode, MENU is used to selectthe rod length. In

Pagina 26 - Campbell Scientific Companies

HydroSense54.3 Description of Water Content Measurement ModeThe Water Content Measurement Mode applies calibration coefficients tothe output of the p