INSTRUCTION MANUAL
CS106 Barometric
Pressure Sensor
Revision: 10/14
Copyright © 1995- 2014
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL CS106 Barometric Pressure Sensor Revision: 10/14 Copyright © 1995- 2014 Campbell Scientific, Inc.

Pagina 2

CS106 Barometric Pressure Sensor 2. The Short Cut installation should place a Short Cut icon on the desktop of your computer. To open Short Cut, cli

Pagina 3 - Limited Warranty

CS106 Barometric Pressure Sensor 5. Under the Available Sensors and Devices list, select Sensors | Meteorological | Barometric Pressure folder. Sele

Pagina 4 - Assistance

CS106 Barometric Pressure Sensor 7. Select any other sensors you have, then finish the remaining Short Cut steps to complete the program. The remain

Pagina 5 - Precautions

CS106 Barometric Pressure Sensor 6.2 Accuracy Total Accuracy***: ±0.3 mb @ 20 °C ±0.6 mb @ 0 to 40 °C ±1 mb @ –20 to 45 °C ±1.5 mb @ –40

Pagina 6

CS106 Barometric Pressure Sensor 7. Installation 7.1 Jumper Settings The CS106 can be operated in one of two modes: shutdown and normal. The mode

Pagina 7 - Table of Contents

CS106 Barometric Pressure Sensor atmosphere, a backplate for mounting the CS106, and hardware for mounting the ENC100 to a tripod, tower, or pole. FI

Pagina 8 - Figures

CS106 Barometric Pressure Sensor 7.3 Wiring 7.3.1 Datalogger Connection To wire an Edlog datalogger, see an older manual at www.campbellsci.com/old-

Pagina 9 - 4. Quickstart

CS106 Barometric Pressure Sensor TABLE 7-1. Signal and Ground Connectors for CS106 Wire CS106 Terminal Datalogger Single-Ended Measurement Datalogg

Pagina 10

CS106 Barometric Pressure Sensor 7.4 Programming Short Cut is the best source for up-to-date datalogger programming code. Programming code is needed

Pagina 11

CS106 Barometric Pressure Sensor 8. Operations 8.1 Multiplier and Offset Calculation The multiplier and offset in the VoltSE() CRBasic instruction c

Pagina 13 - 6.3 General

CS106 Barometric Pressure Sensor 8.3 Long Lead Lengths There is a 0.06 mV/foot voltage drop in the CS106 signal leads. This voltage drop, in long le

Pagina 14 - 7. Installation

CS106 Barometric Pressure Sensor 9. Maintenance and Calibration Since the sensor is semi-sealed, minimum maintenance is required: 1. Visually inspec

Pagina 15

CS106 Barometric Pressure Sensor 14

Pagina 16 - 7.3 Wiring

Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement • Ho

Pagina 17

Appendix A. Importing Short Cut Code mark) begins each line. This character instructs the datalogger compiler to ignore the line when compiling the

Pagina 18 - 7.4 Programming

Appendix B. Example Programs B.1 CR1000 Program Using Sequential Mode This CR1000 program uses the sequential mode, which is the simplest mode and

Pagina 19 - 8. Operations

Appendix B. Example Programs B.2 CR1000 Program Using Pipeline Mode Although this example is for the CR1000, other CRBasic dataloggers, such as the

Pagina 21

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Pagina 22

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Pagina 23

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 24

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Pagina 26

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Pagina 27

Table of Contents Figures 7-1. CS106 jumper set to shutdown mode .... 6 7-2. ENC100 is a very small en

Pagina 28

CS106 Barometric Pressure Sensor 1. Introduction The CS106 measures barometric pressure for the range of 500 to 1100 mb. This range equates to from