Campbell CR850 Especificaciones Pagina 1

Busca en linea o descarga Especificaciones para De medición, control y control Campbell CR850. Campbell CR850 Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - CR800/CR850 Measurement

CR800/CR850 Measurementand Control System OverviewRevision: 9/07Copyright © 2000-2007Campbell Scientific, Inc.

Pagina 2

CR800 and CR850 Overview OV1.3 Power Supply and AC Adapter The CR800 requires a separate 12 V power supply. The PS100 power supply has a 7 amp hour

Pagina 3 - Table of Contents

CR800 and CR850 Overview OV2.3 Instruction Execution within the Datalogger The execution of instructions within the datalogger is accomplished using

Pagina 4 - Figures

CR800 and CR850 Overview is converted to a value determined by the processing included in the instruction, and then the datalogger proceeds to the nex

Pagina 5

CR800 and CR850 Overview conflicting use of measurement hardware. In this scheme the main scan has the highest priority and prevents other sequences

Pagina 6

CR800 and CR850 Overview • Datalogger to datalogger communications – Special PakBus instructions simplify transferring data between dataloggers for d

Pagina 7 - OV1.1.8 Digital I/O (C1-4)

CR800 and CR850 Overview • Updates to DevConfig are available from Campbell Scientific's web site. These may be installed over top of older ver

Pagina 8 - OV1.2.1 CS I/O

CR800 and CR850 Overview OV3.2 Deployment Tab The Deployment Tab allows the user to configure the datalogger prior to deploying it. OV3.2.1 Datalog

Pagina 9 - OV1.2.2 Computer RS-232

CR800 and CR850 Overview security code. If the user enters the Security1 code, the datalogger program can be changed or retrieved or variables can be

Pagina 10 - OV2.2 Programming

CR800 and CR850 Overview as neighbors on the port specified by Selected Port. As you select items in this list, the values of the Begin and End range

Pagina 11 - OV2.3.2 Sequential Mode

CR800 and CR850 Overview OV3.2.3 Advanced Is Router allows you to control whether the datalogger will act as a PakBus router. PakBus Nodes Allocatio

Pagina 13 - OV2.5 PakBus

CR800 and CR850 Overview OV3.3 Logger Control Tab The clock in the PC and the datalogger will be checked every second and the difference displayed.

Pagina 14 - OV3. Device Configurator

CR800 and CR850 Overview OV3.4 Send OS Tab - Downloading an Operating System DevConfig can send operating systems to all Campbell Scientific devices

Pagina 15 - OV3.1 Main DevConfig Screen

CR800 and CR850 Overview OV3.5 Settings Editor Tab The CR800 has a number of properties, referred to as “settings”, some of which are specific to the

Pagina 16 - OV3.2 Deployment Tab

CR800 and CR850 Overview Clicking the Revert to Defaults button on the Settings Editor will send a command to the device to revert to its factory def

Pagina 17 - OV3.2.2 Ports Settings

CR800 and CR850 Overview OV4. Quick Start Tutorial OV4.1 Software Products for the CR800 PC200W Starter Software supports a direct connection betwe

Pagina 18

CR800 and CR850 Overview 2. The CRBasic Editor is a program editor used to create more complex CR800 programs. Short Cut generated programs can be i

Pagina 19 - OV3.2.3 Advanced

CR800 and CR850 Overview OV4.3 Setting the CR800 PakBus Address The CR800 default PakBus address is 1 (Section OV2.5). Unless the CR800 is used in a

Pagina 20 - OV3.3 Logger Control Tab

CR800 and CR850 Overview OV4.4.1 Creating a CR800 Program using Short Cut Objective: Every one second, measure air temperature in degrees C with a Ty

Pagina 21

CR800 and CR850 Overview Step 2 is to select the sensors to be measured. From the Home page, click the Sensors button. The Sensors worksheet is divi

Pagina 22 - OV3.5 Settings Editor Tab

CR800 and CR850 Overview Click on the Wiring Diagram tab to view the sensor wiring diagram, as shown below. Wire the Type T Thermocouple (provided) t

Pagina 23 - OV3.6 Terminal Tab

CR800/CR850 Overview Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bo

Pagina 24 - OV4. Quick Start Tutorial

CR800 and CR850 Overview Click the Home button to continue with Step 4 to complete the program. Step 4: Finish Step 4 is to finish the program. From

Pagina 25

CR800 and CR850 Overview OV4.4.2 Configuring the Setup Tab From the Setup/Connect screen, click on the Connect button to establish communications wit

Pagina 26 - OV4.4 PC200W Software

CR800 and CR850 Overview OV4.4.6 Collect Data Click on the Collect Data tab. From the Collect Data window you can choose what data to collect, and

Pagina 27

CR800 and CR850 Overview OV4.4.7 View Data To view the collected data, click on the View button (located in the upper right hand corner of the main s

Pagina 28

CR800 and CR850 Overview OV4.5 Programming using the CRBasic Program Editor Those users who are moving from the Edlog Program Editor to the CRBasic P

Pagina 29

CR800 and CR850 Overview OV5. Keyboard Display This section illustrates the use of the CR1000KD or the CR850’s on-board keyboard display. The keyboar

Pagina 30

CR800 and CR850 Overview CR1000KD or CR850 Display CAMPBELL SCIENTIFIC CR800 Datalogger 06/18/2000, 18:24:35 CPU: TRIG.CR1 Running. R

Pagina 31 - OV4.4.5 Monitor Data Tables

CR800 and CR850 Overview OV5.1 Data Display Data Run/Stop Program File Ports and Status Configure, Settings List of Data Tables crea

Pagina 32 - OV4.4.6 Collect Data

CR800 and CR850 Overview OV5.1.1 Real Time Tables Public Table1 Temps Tref : 23.0234 TCTemp(1) : 19.6243 TCTemp(2) : 19.3429 TCTemp(3) : 21.2003 F

Pagina 33 - OV4.4.7 View Data

CR800 and CR850 Overview OV5.1.2 Real Time Custom The first time you navigate to Real Time Custom you will need to set up the display. The CR800 wil

Pagina 34

CR800/CR850 Overview Table of Contents OV4.4 PC200W Software... OV-22 OV4.4.1 Creating a

Pagina 35 - OV5. Keyboard Display

CR800 and CR850 Overview OV5.1.3 Final Storage Tables TimeStamp Record Tref TC(1) TC(2) TC(3) "2000-01-03 00:12:38" 0

Pagina 36 - CR1000KD or CR850 Display

CR800 and CR850 Overview OV5.2 Run/Stop Program CPU: ProgramName.CR8 Is Running >* Run on Power Up Stop, Retain Data Stop, De

Pagina 37 - OV5.1 Data Display

CR800 and CR850 Overview OV5.3 File Display Data Run/Stop Program File Ports and Status Configure, Settings New File Name: CPU: .CR8 CPU:

Pagina 38 - CR800 and CR850 Overview

CR800 and CR850 Overview OV5.3.1 File: Edit The CRBasic Program Editor is recommended for writing and editing datalogger programs. Changes in the fi

Pagina 39

CR800 and CR850 Overview OV5.4 Ports and Status List of Status Variables (see Appendix A) Ports Status Table PortStatus (1): OFF Por

Pagina 40

CR800 and CR850 Overview OV5.5 Settings Set Time/Date Settings Display Routes : xxxx StationName : xxxx PakBusAddress : xxxx Securi

Pagina 41

CR800 and CR850 Overview OV5.5.3 Configure Display Set Time/Date Settings Display Light Dark <- * -> Turn Off Display Ba

Pagina 42

CR800 and CR850 Overview OV6. Specifications PROGRAM EXECUTION RATE10 ms to 30 min. @ 10 ms incrementsANALOG INPUTS3 differential (DF) or 6 single-en

Pagina 43

CR800 and CR850 Overview This is a blank page. OV-44

Pagina 44

This is a blank page.

Pagina 45

CR800 and CR850 Overview The CR800 and CR850 provide precision measurement capabilities in a rugged, battery-operated package. The CR800 and CR850 in

Pagina 46

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Pagina 47

CR800 and CR850 Overview Analog Inputs Voltage VoltDiff VoltSE Thermocouple TCDiff TCSE Bridge measurements (use VX) BrFull BrFull6W

Pagina 48

CR800 and CR850 Overview OV1.1.2 Signal Grounds () Signal Grounds () should be used as the reference for Single-ended Analog inputs, Pulse inputs, Ex

Pagina 49 - This is a blank page

CR800 and CR850 Overview OV1.1.9 Pulse Inputs (P1-2) Two Pulse input channels can count pulses from high-level (5 V square wave), switch closure, or

Pagina 50

CR800 and CR850 Overview CS I/O RS232 COMPUTER Pin 5Pin 9Pin 1 Pin 6 FIGURE OV1-3. Serial Communication Interfaces OV1.2.2 Computer RS-232 The CR

Comentarios a estos manuales

Sin comentarios