Campbell 229 Especificaciones Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
229 Heat Dissipation Matric Water Potential Sensor
8: Excitation with Delay (P22) ;Wait 29 more seconds for next reading
1: 1 Ex Channel
2: 0 Delay W/Ex (0.01 sec units)
3: 2900 Delay After Ex (0.01 sec units)
4: 0000 mV Excitation
9: Thermocouple Temp (DIFF) (P14) ;Take 30 second temperature reading
1: 1 Reps
2: 1 2.5 mV Slow Range
3: 4 DIFF Channel
4: 1 Type T (Copper-Constantan)
5: 1 Ref Temp (Deg. C) Loc [ ref_temp ]
6: 4 Loc [ T30sec_1 ]
7: 1.0 Mult
8: 0.0 Offset
10: Do (P86) ;turn off CE8
1: 52 Set Port 2 Low
11: Z=X-Y (P35) ;Calculate delta T
1: 4 X Loc [ T30sec_1 ]
2: 3 Y Loc [ T1sec_1 ]
3: 5 Z Loc [ deltaT_1 ]
12: Do (P86) ;Save readings to final storage
1: 10 Set Output Flag High (Flag 0)
13: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 229 Array ID
14: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
15: Sample (P70)
1: 1 Reps
2: 2 Loc [ Tinit_1 ]
16: Sample (P70)
1: 1 Reps
2: 5 Loc [ deltaT_1 ]
17: Do (P86) ;Disable flag 1
1: 21 Set Flag 1 Low
18: End (P95)
15
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 33 34

Comentarios a estos manuales

Sin comentarios