REAL TIME MONITORING SOFTWARE (RTMS)INSTRUCTION MANUAL2/95COPYRIGHT (c) 1995 CAMPBELL SCIENTIFIC, INC.

Pagina 2 - LIMITED WARRANTY

3-1SECTION 3. GETTING STARTED WITH RTMS3.1 RTMS INSTALLATIONTo install RTMS, select a full OS/2 screen or anOS/2 window. Change to the drive contai

Pagina 3 - LICENSE FOR USE

SECTION 3. RTMS INSTALLATION3-23.3 RTMS STARTUP OVERVIEWCampbell Scientific dataloggers are generalpurpose and require programming for specificappli

Pagina 4 - TABLE OF CONTENTS

4-1SECTION 4. DLSMGR4.1 INTRODUCTIONDataLoggeR Services ManaGeR (DlsMgr)provides all communication with the dataloggernetwork. RTMS users do not in

Pagina 5 - GLOSSARY

SECTION 4. DLSMGR4-2remote, the RF base will direct the packets tothe CR10T using the specified path and returnthe response as soon as possible.If di

Pagina 6

5-1SECTION 5. NETADMIN5.1 OVERVIEWNetAdmin provides seven basic functions forsetting up and maintaining the network. Thenetwork health is displayed

Pagina 7

SECTION 5. NETADMIN5-2parent-child organization or a tree structure.Basically the structure starts with the Computer(PC1) at the top, a datalogger (C

Pagina 8 - SYSTEM RESOURCES

SECTION 5. NETADMIN5-3FIGURE 5-1. Initial NetAdmin ScreenAs the network is constructed, the left part ofthe screen will visually indicate the networ

Pagina 9 - 2.3 RESTARTING OS/2

SECTION 5. NETADMIN5-4The DO___RETRIES USING A ____ SECPERIOD THEN USE ______ SEC. promptsallow the scheduling of fast and slow retries.When an opera

Pagina 10 - PROGRAMS

SECTION 5. NETADMIN5-5Direct Connect (SC32A) − Each remote data-logger is entered as a node (child node of PC1).No other nodes are necessary. Each

Pagina 11 - 3.3 RTMS STARTUP OVERVIEW

SECTION 5. NETADMIN5-65.2 NETWORK HEALTHFIGURE 5-3. Main NetAdmin Screen Showing Network HealthWhen a description is made active, the com-municatio

Pagina 12 - SECTION 4. DLSMGR

LIMITED WARRANTYCampbell Scientific, Inc. warrants that the magnetic diskette on which the accompanying computersoftware is recorded and the documenta

Pagina 13

SECTION 5. NETADMIN5-7FIGURE 5-4. Clock Check/Set View(at 12:00) setting the datalogger clock back to11:59 will cause an additional 12:00 output tob

Pagina 14 - SECTION 5. NETADMIN

SECTION 5. NETADMIN5-8You can manually force a retry by selecting theKICK button in the CURRENT TRANSACTIONbox. The STATION box displays the clockse

Pagina 15

SECTION 5. NETADMIN5-9When all stations that need to have programsdownloaded are in the queue, select the STARTbutton. The programs will be download

Pagina 16

SECTION 5. NETADMIN5-10The RF Link Test also returns the signature ofthe prom in the Remote RF95T. Featuring theRFBASE address in the switch setting

Pagina 17

6-1SECTION 6. RTM (REAL TIME MONITOR)RTM is used to monitor data values from stations in the RTMS network. RTM offers a variety of datadisplays incl

Pagina 18

SECTION 6. RTM (REAL TIME MONTIOR)6-26.1.2 CREATING A TEMPLATECreating a template consists of adding thedesired displays to the template. Data disp

Pagina 19 - 5.3 CLOCK SET/CHECK

SECTION 6. RTM (REAL TIME MONITOR)6-3FIGURE 6-2. RTM Screen Showing Station.Table.Field for a Numeric DisplayTo move a display, place the mouse poin

Pagina 20

SECTION 6. RTM (REAL TIME MONTIOR)6-4The Station.Table.Field can be selected from alist of those available (see Figure 6-2). This listis displayed b

Pagina 21 - 5.4 PROGRAM DOWNLOAD

SECTION 6. RTM (REAL TIME MONITOR)6-56.1.10 STARTING RTM IN THE MONITOR MODE.RTM normally starts in the edit mode. To haveRTM automatically start m

Pagina 22 - 5.6 RF LINK TEST

7-1SECTION 7. DATA COLLECTION (DBSELECT)DBSelect is used to select the data for archival or routing to a different application or a different compute

Pagina 23

LICENSE FOR USEThis software is protected by both United States copyright law and international copyright treatyprovisions. You may copy it onto a co

Pagina 24 - 6.1 EDIT MODE

SECTION 7. DATA COLLECTION (DBSELECT)7-2A typical data collection sequence would be:1. A Data Advise is sent to each station.2. DLSMGR polls for da

Pagina 25

SECTION 7. DATA COLLECTION (DBSELECT)7-3Ack. Named PipeTCP\IP NetworkVAX,OS/2,HP9000, ...machineOS/2MachineTCPC or userTCP programTCPSDBSelectFIGURE

Pagina 26

SECTION 7. DATA COLLECTION (DBSELECT)7-47.3.6 SELECTING WHAT DATA IS COLLECTED.To select data for collection, select a station(from the station list

Pagina 27

SECTION 7. DATA COLLECTION (DBSELECT)7-5FIGURE 7-3. Selection of Data to be Collected7.4 HOLE COLLECTION STATUS ANDMANUAL HOLE COLLECTIONSelecting

Pagina 28 - 6.2 MONITOR MODE

SECTION 7. DATA COLLECTION (DBSELECT)7-6FIGURE 7-4. Hole Collection Viewhole of the specified range will be inserted intothe queue for each station

Pagina 29 - HOLE COLLECTION THEORY

8-1SECTION 8. FILES, PROTOCOLS, AND UTILITIES8.1 LOG FILESLog files are produced for several reasons.Documenting events that occurred is a primaryre

Pagina 30 - 7.3 RUNNING DBSELECT

SECTION 8. FILES, PROTOCOLS, AND UTILITIES8-2be able to manually find the missing data inQUEUE.DAT. QUEUE.DAT is not intended tobe used as a reliab

Pagina 31

SECTION 8. FILES, PROTOCOLS, AND UTILITIES8-3• StationName Space TableName SpaceBeginning Space End Space Flag.• StationName and TableName limited

Pagina 32

SECTION 8. FILES, PROTOCOLS, AND UTILITIES8-4Limitations and issues of concern to the clientapplication include:1. Each record must be acknowledged

Pagina 33 - MANUAL HOLE COLLECTION

SECTION 8. FILES, PROTOCOLS, AND UTILITIES8-5FIGURE 8.5-2. Server State DiagramKey concepts from the state diagrams areshown in the following tables

Pagina 34

iREAL TIME MONITORING SOFTWARE (RTMS)TABLE OF CONTENTSPAGESECTION 1. RTMS SYSTEM OVERVIEW...

Pagina 35 - 8.1 LOG FILES

SECTION 8. FILES, PROTOCOLS, AND UTILITIES8-6Send Ack − The send acknowledgment actionis done in response to the Record Rdy event,after the record i

Pagina 36 - 8.2 EXTRACT UTILITY

SECTION 8. FILES, PROTOCOLS, AND UTILITIES8-7Decimal = "DECIMAL(" Digit [ Digit ] "," Digit [ Digit ] ")".VarChar = &qu

Pagina 37 - PROTOCOL

SECTION 8. FILES, PROTOCOLS, AND UTILITIES8-8• TOACI1 indicates the file type and is alwayspresent.• MD91 is the user specified station name.• Mi

Pagina 38

A-1APPENDIX A. TROUBLESHOOTING THE RTMS NETWORKSA.1 STATION TESTThe best tool for determining network status isNetAdmin. Examine the network health

Pagina 39

APPENDIX A. TROUBLESHOOTINGA-2A.2 COMMUNICATION PROBLEMSThe approach taken here is to isolate wherecommunication is having difficulty and thenattemp

Pagina 40

APPENDIX A. TROUBLESHOOTINGA-3cable. A straight through 9-pin cableconnects the SC32A to the datalogger.• With RAD modems and the SC932, verifythe

Pagina 41 - DBSELECT

APPENDIX A. TROUBLESHOOTINGA-4remote site answering and then a high pitchtone, then the phone line is probably fine.• If the modem dials but the re

Pagina 42

APPENDIX A. TROUBLESHOOTINGA-5Things to check include:• Ensure that the correct COM port isselected in the Net Description for the BaseMD9.• Is the

Pagina 43 - A.1 STATION TEST

APPENDIX A. TROUBLESHOOTINGA-6A2.4 RADIO (RF)This section deals with troubleshooting radionetwork from the software perspective. It doesnot give sp

Pagina 44 - A.2 COMMUNICATION PROBLEMS

APPENDIX A. TROUBLESHOOTINGA-7response to transmissions the radio hears. Ifthe frequency is in use, turn off the radio andrepeat the power up test.W

Pagina 45

APPENDIX A. TROUBLESHOOTING THE RTMS NETWORKSA.1 Sample ASCII File Created by DBSelect...

Pagina 46

APPENDIX A. TROUBLESHOOTINGA-8'08-18-94 15:30:00','S','PC1','PC1','Transaction was canceled by client.&a

Pagina 47

APPENDIX A. TROUBLESHOOTINGA-9'08-18-94 15:21:42','W','PC1','PC1','RTM:StripChart, Data TimeStamp greate

Pagina 48

APPENDIX A. TROUBLESHOOTINGA-10First message indicates the RTM or DBSelectrequested a specific range of data using holecollection. Second message in

Pagina 49 - ROUTING DATA

APPENDIX A. TROUBLESHOOTINGA-11set/checked automatically (must be enabled) ormanually. Second message is from thedatalogger indicating its clock was

Pagina 50

APPENDIX A. TROUBLESHOOTINGA-12or device, DlsMgr may be attemptingcommunication with the wrong device.The third can indicate that DlsMgr is retryingo

Pagina 51 - THEY MEAN

APPENDIX A. TROUBLESHOOTINGA-13the files contained there at all. The seconderror indicates the DBSelect could remove a filefrom the shadow directory

Pagina 52

GLOSSARYAcknowledged Named Pipe − See NamedPipe. Exchange of data through a named pipewhere the program or process (client) receivingdata must acknow

Pagina 53

Hole − See hole collection. Because of the waycurrent and older datalogger data are collectedsimultaneously, there can be sequences ofolder data that

Pagina 54

Repeater − A radio (RF) site that relays packetsof information to a remote site. Used to extendthe range of radio transmissions. Any remotedatalogge

Pagina 55

1-1SECTION 1. RTMS SYSTEM OVERVIEWReal Time Monitoring Software (RTMS) is PC software designed to enhance the capabilities of the CR10Tand future Cam

Pagina 56

REAL TIME MONITORING SOFTWARE1-2COMPONENTS OF RTMSBMP − Block Mode Protocol, use tocommunicate with dataloggers, etc.DBSelect − Data collection for s

Pagina 57

2-1SECTION 2. OS/2 OPERATING SYSTEM2.1 USER INTERFACEBefore RTMS can be installed, OS/2 (Version2.1 or newer) must be installed and running.The SYST

Pagina 58

SECTION 2. OS/2 OPERATING SYSTEM2-2• Sluggish responses to mouse and keyboard.• Low memory warning on NETADMIN net-work health screen.• Real time